Ultrasound propagation characteristics within the bone tissue of miniature ultrasound probes: implications for the spinal navigation of pedicle screw placement

微型超声探头在骨组织内的超声传播特性:对椎弓根螺钉置入脊柱导航的意义

阅读:1

Abstract

BACKGROUND: The accuracy of pedicle screw fixation is crucial for patient safety. Traditional navigation methods based on computed tomography (CT) imaging have several limitations. Therefore, this study aimed to investigate the ultrasonic propagation characteristics of bone tissue and their relationship with CT imaging results, as well as the potential application of ultrasound navigation in pedicle screw fixation. METHODS: The study used three bovine spine specimens (BSSs) and five human vertebral allograft bones (HABs) to progressively decrease the thickness of the cancellous bone layer, simulating the process of pedicle screw perforation. Five unfocused miniature ultrasound probes with frequencies of 2.2, 2.5, 3, 12, and 30 MHz were employed for investigating the ultrasonic propagation characteristics of cancellous and cortical bone through ultrasound transmission and backscatter experiments. The CT features of the bone tissue was obtained with the Skyscan 1174 micro-CT scanner (Bruker, Billerica, MA, USA). RESULTS: The experimental results demonstrated that low-frequency (2-3 MHz) ultrasound effectively penetrated the cancellous bone layer up to a depth of approximately 5 mm, with an attenuation coefficient below 10 dB/cm. Conversely, high-frequency (12 MHz) ultrasound exhibited significant signal attenuation in cancellous bone, reaching up to 55.8 dB/cm. The amplitude of the backscattered signal at the cancellous bone interface exhibited a negative correlation with the bone sample thickness (average r=-0.84), meaning that as the thickness of the cancellous bone layer on the cortical bone decreases, the backscattered signal amplitude gradually increases (P<0.05). Upon reaching the cortical bone interface, there was a rapid surge in echo signal amplitude, up to 8 times higher. Meanwhile, the statistical results indicated a significant correlation between the amplitude of the echo signal and the micro-CT scanning results of bone trabecular structure. CONCLUSIONS: Theoretically, using multiple ultrasonic probes (≥3) and regions of interest (ROIs) (≥5) has the potential to provide surgeons with early warning signals for pedicle perforation based on three or more successive increases in echo signal amplitude or a sudden substantial increase. The statistical results indicate a significant correlation between the amplitude of the echo signal and the micro-CT scanning results of bone trabeculae, suggesting the potential use of ultrasound as opposed to CT for real-time intraoperative bone navigation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。