Combining Raman Microspectroscopy and X-ray Microcomputed Tomography for the Study of Bone Quality in Apolipoprotein-Deficient Animal Models

结合拉曼显微光谱和X射线微型计算机断层扫描技术研究载脂蛋白缺乏动物模型的骨骼质量

阅读:1

Abstract

Raman microspectroscopy and X-ray microcomputed tomography (micro-CT) were used for assessment of the quality of the femur and tibia bones in apolipoprotein-deficient mice compared to control littermates. The cortical and trabecular bone was investigated separately. Raman spectra revealed no differences in the bioapatite-to-collagenous matrix ratio of the cortical bone. The quantities of calcium and collagen, which were measured using atomic absorption spectrometry and thermogravimetric analysis, respectively, were also found to be equal in the two groups. Density and morphometric parameters, which were measured using micro-CT, verified the cortical mineral stability. Bone quality indices were measured using Raman spectra. A decreased collagen crosslink (trivalent-to-divalent) ratio revealed delayed maturation of the collagen network. Such a decrease has been reported in the literature to be connected to decreased bone strength. For the trabecular bone, micro-CT revealed severe osteoporosis in the knock-out group, which was evident from a decreased mineral density, trabecular thickness and increased bone surface/volume ratio. The trabecular bone was not accessible for Raman spectroscopy. According to these results, the cortical and trabecular femur bone is expected to exhibit proneness to fracturing, each for a different reason. A combination of the two techniques was regarded as necessary for an overall assessment of bone quality.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。