Stroke lesion size - Still a useful biomarker for stroke severity and outcome in times of high-dimensional models

中风病灶大小——在高维模型时代,它仍然是中风严重程度和预后的一个有用生物标志物

阅读:1

Abstract

BACKGROUND: The volumetric size of a brain lesion is a frequently used stroke biomarker. It stands out among most imaging biomarkers for being a one-dimensional variable that is applicable in simple statistical models. In times of machine learning algorithms, the question arises of whether such a simple variable is still useful, or whether high-dimensional models on spatial lesion information are superior. METHODS: We included 753 first-ever anterior circulation ischemic stroke patients (age 68.4±15.2 years; NIHSS at 24 h 4.4±5.1; modified Rankin Scale (mRS) at 3-months median[IQR] 1[0.75;3]) and traced lesions on diffusion-weighted MRI. In an out-of-sample model validation scheme, we predicted stroke severity as measured by NIHSS 24 h and functional stroke outcome as measured by mRS at 3 months either from spatial lesion features or lesion size. RESULTS: For stroke severity, the best regression model based on lesion size performed significantly above chance (p < 0.0001) with R(2) = 0.322, but models with spatial lesion features performed significantly better with R(2) = 0.363 (t(752) = 2.889; p = 0.004). For stroke outcome, the best classification model based on lesion size again performed significantly above chance (p < 0.0001) with an accuracy of 62.8%, which was not different from the best model with spatial lesion features (62.6%, p = 0.80). With smaller training data sets of only 150 or 50 patients, the performance of high-dimensional models with spatial lesion features decreased up to the point of being equivalent or even inferior to models trained on lesion size. The combination of lesion size and spatial lesion features in one model did not improve predictions. CONCLUSIONS: Lesion size is a decent biomarker for stroke outcome and severity that is slightly inferior to spatial lesion features but is particularly suited in studies with small samples. When low-dimensional models are desired, lesion size provides a viable proxy biomarker for spatial lesion features, whereas high-precision prediction models in personalised prognostic medicine should operate with high-dimensional spatial imaging features in large samples.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。