Validation of a semi-automated method to quantify lesion volume changes in multiple sclerosis on 2D proton-density-weighted scans based on image subtraction

基于图像减影法的二维质子密度加权扫描中多发性硬化病灶体积变化量化半自动方法的验证

阅读:1

Abstract

BACKGROUND: The detection and quantification of changes in white matter lesions in the brain is important to monitor treatment effects in patients with multiple sclerosis (MS). Existing automatic tools predominantly require FLAIR images as input which are not always available, or only focus on new/enlarging activity. Therefore, we developed and validated a semi-automated method to quantify lesion volume changes based on 2D proton-density (PD)-weighted images and image subtraction. This semi-automated method provides insight in both "positive" activity (defined as new and enlarging lesions) and "negative" activity (disappearing and shrinking lesions). METHODS: Yearly MRI scans of patients with early MS from the REFLEX/REFLEXION studies were used. The maximum follow-up period was 5 years. Two PD-weighted images were normalized, registered to a common halfway-space, intensity-matched, and subsequently subtracted. Within manual lesion masks, lesion changes were quantified using a subtraction intensity threshold and total lesion volume change (TLVC) was calculated. Reproducibility was measured by assessing transitivity, specifically, we calculated the intraclass correlation coefficient for the absolute agreement (ICC(trans)) and the difference (Δ(trans)) between the direct one-step and indirect multi-step measurements of TLVC between two visits. Accuracy was assessed by calculating both the intraclass correlation coefficient for absolute agreement (ICC(acc)) and the difference (Δ(acc)) between the one-step semi-automated TLVC and manually measured lesion volume change (numerical difference) between two visits. Spearman's correlations (r(s)) were used to assess the relation of global and central atrophy, manually measured T2 lesion volume, and lesion volume change with the method's performance as reflected by the difference measures |Δ(trans)| and Δ(acc). An alpha of 0.05 was used as the cut-off for significance. RESULTS: Reproducibility was excellent, with ICC(trans) values ranging from 0.90 to 0.96. Accuracy was good overall, with ICC(acc) values ranging from 0.67 to 0.86. The standard deviation of Δ(trans) ranged from 0.25 to 0.86 mL. The mean of Δ(acc) ranged from 0.11 to 0.37 mL and was significantly different from zero. Both global and central atrophy significantly correlated with lower reproducibility (correlation of |Δ(trans)| with global atrophy, r(s) = -0.19 to -0.28, and correlation of |Δ(trans)| with central atrophy, r(s) = 0.22 to 0.34). There was generally no significant correlation between global/central atrophy and accuracy. Higher lesion volume was significantly correlated with lower reproducibility (r(s) = 0.62). Higher lesion volume change was significantly correlated with lower reproducibility (r(s) = 0.22) and lower accuracy (correlation of Δ(acc) with lesion volume change, r(s) = -0.52). DISCUSSION: The semi-automated method to quantify lesion volume changes has excellent reproducibility and overall good accuracy. The amount of atrophy and especially lesion volume (change) should be taken into account when applying this method, as an increase in these variables might affect the quality of the results. CONCLUSION: Overall, the semi-automated subtraction method allows a valid and reliable quantitative investigation of lesion volume changes over time in (early) MS for follow-up periods up to 5 years.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。