Meibography signal intensity as a novel image biomarker for meibomian gland function: evidence from cross-sectional and longitudinal analyses

睑板腺成像信号强度作为睑板腺功能的新型影像生物标志物:来自横断面和纵向分析的证据

阅读:1

Abstract

BACKGROUND: Meibomian gland dysfunction (MGD), one of the most common ocular surface diseases, can induce dry eye and reduce patients' quality of life. Methodological limitations have resulted in contradictory interpretations of gland function. This study sought to investigate the correlation between meibography signal intensity (SI) and meibomian gland (MG) function and to validate an MGD classification strategy based on different levels of SI. METHODS: A multicenter, cross-sectional analysis was conducted on 817 eyes from 361 patients with MGD and 52 healthy controls. Additionally, 78 eyes from 39 patients with MGD who had undergone LipiFlow treatment were recruited for longitudinal analyses. The SI value was obtained via meibography using an automated analyzer, and all participants underwent ocular surface examinations. A cross-sectional analysis was performed to determine SI distribution and its relationship to clinical characteristics via a generalized estimating equation model. Longitudinal analyses were conducted on the treatment cohort using a mixed-effects model to explore the outcome in different SI levels. RESULTS: Regression analysis revealed significant correlations between SI and lipid layer thickness (β=0.016), meibum expressibility (β=-0.676), meibum quality (β=-0.251), and fluorescein-stained tear-film break-up time (FBUT) (β=0.064) (all P values <0.001 for the above associations). Low-level SI MGD cases exhibited the most severe clinical signs, including the worst meibum expressibility (16% for level 3) and quality scores (19% for level 3), the shortest FBUT (3.82±0.13 s), and the thinnest lipid layer (65.68±2.58 nm), (all P values <0.05, respectively). Patients with medium SI showed the lowest ocular surface disease index (OSDI) value (26.64±1.06), the longest FBUT (4.56±0.08 s), and the thickest lipid layer (80.20±2.90 nm). After treatment, the high SI values reduced significantly at each follow-up point compared to baseline (all P values <0.05). The medium SI group demonstrated the greatest improvement in symptoms and signs, followed by the high SI group, and the low SI group. CONCLUSIONS: Automated measurements of SI can effectively reflect MG secretory activity. The proposed low, medium, and high SI classifications represent different functional subtypes of MGD.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。