Accuracy and reliability of 3D cephalometric landmark detection with deep learning

基于深度学习的三维头影测量标志点检测的准确性和可靠性

阅读:3

Abstract

BACKGROUND: Three-dimensional (3D) landmark detection is essential for assessing craniofacial growth and planning surgeries, such as orthodontic, orthognathic, traumatic, and plastic procedures. This study aimed to develop an automatic 3D landmarking model for oral and maxillofacial regions and to validate its accuracy, robustness and generalizability in both spiral computed tomography (SCT, 41 landmarks) and cone-beam computed tomography (CBCT, 14 landmarks) scans. METHODS: The model was implemented using an optimized lightweight 3D U-Net network architecture. Its accuracy, robustness and generalizability were thoroughly evaluated and validated through a multicenter retrospective diagnostic study. The model was trained and tested on a data set of 480 SCT and 240 CBCT cases. An additional inference on a different data set of 320 SCT and 150 CBCT cases was performed. Mean radial error (MRE) and success detection rate within 2-, 3-, and 4-mm error thresholds were measured as the primary evaluation metrics. Error analyses for landmark detection along each coordinate axis were performed. Consistency tests among observers were conducted. RESULTS: The average MRE for both SCT and CBCT was consistently below 1.3 mm and, notably, below 1.4 mm in complex conditions, such as malocclusion, missing dental landmarks, and the presence of metal artifacts. No significant differences in MRE and SDR at 2-4 mm were observed between external and internal SCT and CBCT sets. SCT bone landmarks were more precise than dental ones, with no difference between bone/soft tissue and dental/soft tissue. CBCT dental landmarks exhibited greater precision compared to bone landmarks. A detailed error analysis across the coordinate axes showed that the coronal axis had the highest error rates. The implementation of this model significantly improved the landmarking proficiency of senior and junior specialists by 15.9% and 28.9%, respectively, while also achieving a 6-9.5-fold acceleration in GUI interaction time. CONCLUSIONS: This study shows that the AI-driven model delivers high-precision 3D localization of oral and maxillofacial landmarks, even in complex scenarios. The model demonstrates potential as a promising computer-aided tool to assist specialists in conducting accurate and efficient localization analyses; however, its robustness and generalizability require prospective clinical validation to ensure utility across varied experience levels.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。