[Development and validation of a clinical automatic diagnosis system based on diagnostic criteria for temporomandibular disorders]

[基于颞下颌关节紊乱诊断标准的临床自动诊断系统的开发与验证]

阅读:2

Abstract

OBJECTIVE: To develop a clinical automated diagnostic system for temporomandibular disorders (TMD) based on the diagnostic criteria for TMD (DC/TMD) to assist dentists in making rapid and accurate clinical diagnosis of TMD. METHODS: Clinical and imaging data of 354 patients, who visited the Center for TMD & Orofacial Pain at Peking University Hospital of Stomatology from September 2023 to January 2024, were retrospectively collected. The study developed a clinical automated diagnostic system for TMD using the DC/TMD, built on the. NET Framework platform with branching statements as its internal structure. Further validation of the system on consistency and diagnostic efficacy compared with DC/TMD were also explored. Diagnostic efficacy of the TMD clinical automated diagnostic system for degenerative joint diseases, disc displacement with reduction, disc displacements without reduction with limited mouth opening and disc displacement without reduction without limited mouth opening was evaluated and compared with a specialist in the field of TMD. Accuracy, precision, specificity and the Kappa value were assessed between the TMD clinical automated diagnostic system and the specialist. RESULTS: Diagnoses for various TMD subtypes, including pain-related TMD (arthralgia, myalgia, headache attributed to TMD) and intra-articular TMD (disc displacement with reduction, disc displacement with reduction with intermittent locking, disc displacement without reduction with limited opening, disc displacement without reduction without limited opening, degenerative joint disease and subluxation), using the TMD clinical automated diagnostic system were completely identical to those obtained by the TMD specialist based on DC/TMD. Both the system and the expert showed low sensitivity for diagnosing degenerative joint disease (0.24 and 0.37, respectively), but high specificity (0.96). Both methods achieved high accuracy (> 0.9) for diagnosing disc displacements with reduction and disc displacements without reduction with limited mouth opening. The sensitivity for diagnosing disc displacement without reduction without limited mouth opening was only 0.59 using the automated system, lower than the expert (0.87), while both had high specificity (0.92). The Kappa values for most TMD subtypes were close to 1, except the disc displacement without reduction without limited mouth opening, which had a Kappa value of 0.68. CONCLUSION: This study developed and validated a reliable clinical automated diagnostic system for TMD based on DC/TMD. The system is designed to facilitate the rapid and accurate diagnosis and classification of TMD, and is expected to be an important tool in clinical scenarios.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。