Standardization of a protocol for shotgun proteomic analysis of saliva

唾液散弹枪蛋白质组学分析方案的标准化

阅读:8
作者:Talita Mendes da Silva Ventura, Nathalia Regina Ribeiro, Aline Salgado Dionizio, Isabela Tomazini Sabino, Marília Afonso Rabelo Buzalaf

Conclusions

The standardization of protocol for salivary proteomic analysis was satisfactory, since the identification detected typical salivary proteins, among others. The results indicate that using the column for depletion of albumin and IgG is not necessary and that performing individual analysis of saliva samples is possible.

Material and methods

Saliva samples were collected from 10 healthy volunteers. In the first test, the necessity for using an albumin and IgG depletion column was evaluated, employing pooled samples from the 10 volunteers. In the second test, the analysis of the pooled samples was compared with individual analysis of one sample. Salivary proteins were extracted and processed for analysis by LC-ESI-MS/MS.

Methods

Saliva samples were collected from 10 healthy volunteers. In the first test, the necessity for using an albumin and IgG depletion column was evaluated, employing pooled samples from the 10 volunteers. In the second test, the analysis of the pooled samples was compared with individual analysis of one sample. Salivary proteins were extracted and processed for analysis by LC-ESI-MS/MS.

Objective

This study compared methodologies to extract salivary proteins for proteomic analysis. Material and

Results

In the first test, we identified only 35 proteins using the albumin and IgG depletion column, while we identified 248 proteins without using the column. In the second test, the pooled sample identified 212 proteins, such as carbonic anhydrase 6, cystatin isoforms, histatins 1 and 3, lysozyme C, mucin 7, protein S100A8 and S100A9, and statherin, while individual analysis identified 239 proteins, among which are carbonic anhydrase 6, cystatin isoforms, histatin 1 and 3, lactotransferrin, lyzozyme C, mucin 7, protein S100A8 and S100A9, serotransferrin, and statherin. Conclusions: The standardization of protocol for salivary proteomic analysis was satisfactory, since the identification detected typical salivary proteins, among others. The results indicate that using the column for depletion of albumin and IgG is not necessary and that performing individual analysis of saliva samples is possible.