Amorphous Albumin Gadolinium-Based Nanoparticles for Ultrahigh-Resolution Magnetic Resonance Angiography

用于超高分辨率磁共振血管造影的非晶态白蛋白钆基纳米颗粒

阅读:1

Abstract

Magnetic resonance angiography (MRA) contrast agents are extensively utilized in clinical practice due to their capability of improving the image resolution and sensitivity. However, the clinically approved MRA contrast agents have the disadvantages of a limited acquisition time window and high dose administration for effective imaging. Herein, albumin-coated gadolinium-based nanoparticles (BSA-Gd) were meticulously developed for in vivo ultrahigh-resolution MRA. Compared to Gd-DTPA, BSA-Gd exhibits a significantly higher longitudinal relaxivity (r(1) = 76.7 mM(-1) s(-1)), nearly 16-fold greater than that of Gd-DTPA, and an extended blood circulation time (t(1/2) = 40 min), enabling a dramatically enhanced high-resolution imaging of microvessels (sub-200 μm) and low dose imaging (about 1/16 that of Gd-DTPA). Furthermore, the clinically significant fine vessels were successfully mapped in large mammals, including a circle of Willis, kidney and liver vascular branches, tumor vessels, and differentiated arteries from veins using dynamic contrast-enhanced MRA BSA-Gd, and have superior imaging capability and biocompatibility, and their clinical applications hold substantial promise.