Improved accuracy of myocardial perfusion SPECT for the detection of coronary artery disease using a support vector machine algorithm

利用支持向量机算法提高心肌灌注SPECT检测冠状动脉疾病的准确性

阅读:1

Abstract

We aimed to improve the diagnostic accuracy of automatic myocardial perfusion SPECT (MPS) interpretation analysis for the prediction of coronary artery disease (CAD) by integrating several quantitative perfusion and functional variables for noncorrected (NC) data by Support Vector Machine (SVM) algorithm, a computer method for machine learning. METHODS: Rest-stress gated (99m)Tc MPS NC studies (n = 957) from 623 consecutive patients with correlating invasive coronary angiography and 334 with a low likelihood of CAD (<5%) were assessed. Stenosis ≥50% in left main or ≥70% in all other vessels was considered abnormal. Total perfusion deficit (TPD) was computed automatically. In addition, ischemic changes (ISCHs) and ejection fraction changes (EFCs) between stress and rest were derived by quantitative software. The SVM was trained using a group of 125 patients (25 with low-likelihood, 25 with 0-vessel, 25 with 1-vessel, 25 with 2-vessel, and 25 with 3-vessel CAD) with the above quantitative variables and second-order polynomial fitting. The remaining patients (n = 832) were categorized using probability estimates, with CAD defined as a probability estimate ≥ 0.50. The diagnostic accuracy of SVM was also compared with visual segmental scoring by 2 experienced readers. RESULTS: The sensitivity of SVM (84%) was significantly better than ISCH (75%, P < 0.05) and EFC (31%, P < 0.05). The specificity of SVM (88%) was significantly better than TPD (78%, P < 0.05) and EFC (77%, P < 0.05). The diagnostic accuracy of SVM (86%) was significantly better than TPD (81%), ISCH (81%), or EFC (46%) (P < 0.05 for all). The receiver-operating-characteristic (ROC) area under the curve for SVM (0.92) was significantly better than TPD (0.90), ISCH (0.87), and EFC (0.64) (P < 0.001 for all). The diagnostic accuracy of SVM was comparable to the overall accuracy of both visual readers (86% vs. 84%, P = NS). The ROC area under the curve for SVM (0.92) was significantly better than that of both visual readers (0.87 and 0.88, P < 0.03). CONCLUSION: Computational integration of quantitative perfusion and functional variables using the SVM approach significantly improves the diagnostic accuracy of MPS and can significantly outperform visual assessment based on ROC analysis.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。