Is Ti-Coated PEEK Superior to PEEK for Lumbar and Cervical Fusion Procedures? A Systematic Review and Meta-Analysis

钛涂层PEEK在腰椎和颈椎融合手术中是否优于PEEK?一项系统评价和荟萃分析

阅读:2

Abstract

Background/Objectives: Utilization of polyetheretherketone (PEEK) cages for spinal fusion has surged in the U.S., yet comprehensive comparisons evaluating its postoperative effectiveness with alternative materials remain limited. This systematic review investigates the efficacy of PEEK cages against traditional fusion materials across various surgery types, elucidating PEEK's impact on fusion rates, postoperative outcomes, and long-term success. Methods: A systematic search of PubMed, CINAHL, Scopus, Embase, and Web of Science was conducted through 14 October 2024. Included studies were randomized controlled trials (RCTs) comparing PEEK cages with titanium, silicon nitride, and metal-coated PEEK cages for anterior cervical discectomy and fusion (ACDF), posterior lumbar interbody fusion (PLIF), and transforaminal lumbar interbody fusion (TLIF). Article quality was assessed using GRADE criteria. Results: From 288 initially screened articles, 25 RCTs involving 2046 patients (mean follow-up 23.1 ± 18.2 months) met inclusion criteria and were determined as moderate (n = 21) or high (n = 4) quality. Fusion rates by cage material for PEEK (n = 1041), Ti-PEEK (n = 291), and titanium (n = 53) were 85.63 ± 18.00%, 80.05 ± 19.9%, and 92.75 ± 11.31%, respectively. In ACDF, titanium cages achieved higher fusion rates than PEEK (100% vs. 94%). In PLIF and TLIF, coated PEEK outperformed uncoated PEEK (75% vs. 71% and 94% vs. 84%, respectively). Uncoated PEEK achieved fusion rates of 94.04 ± 5.04% for ACDF, 71.21 ± 21.93% for PLIF, and 83.50 ± 24.66% for TLIF, with titanium outperforming PEEK in early fusion outcomes. Coated PEEK demonstrated potential improvements in fusion rates over uncoated PEEK in PLIFs and TLIFs. Conclusions: Selection of cage material for spinal fusions should be tailored to surgical requirements and patient needs. While titanium and PEEK are effective, their performance varies across contexts. New materials and surface modifications may enhance these outcomes further, warranting future research in long-term studies and development of novel materials. These findings can help surgeons choose cage materials according to procedure type, patient characteristics, and imaging needs.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。