Rethinking Access in BEVAR: Single-Center Experience of the Feasibility of Upward-Facing Branches

重新思考BEVAR的就诊方式:单中心向上分支可行性的经验

阅读:1

Abstract

This is a single-center study about upward facing in branched endovascular aortic repair. Background: The evolution of branched endovascular aortic repair (BEVAR) has introduced upward-facing branches as a novel approach to facilitate exclusive transfemoral access in complex aortic aneurysm repair. This study evaluates the feasibility, safety, and early outcomes of custom-made BEVAR devices incorporating upward-facing branches in patients with cranially oriented renal arteries. The investigation further aims to analyze the technical success and mid-term outcomes related to these novel devices, as well as to identify any challenges or complications specific to the use of upward-facing branches in clinical practice. Methods: We retrospectively analyzed 17 patients treated at a single center between January 2020 and December 2024 using custom-made Cook Medical branched stent grafts with at least one upward-facing branch. Demographics, comorbidities, target vessel details, bridging stent graft (BSG) configurations, and procedure-related complications were collected. The primary endpoints were technical success and branch patency. Secondary endpoints included short- and mid-term branch-related complications. Results: The cohort had a mean age of 70 years, with hypertension (88%) and coronary artery disease (47%) being common comorbidities. Technical success was achieved in 100% of cases. The left renal artery was the most frequently targeted vessel (63.2%). Most upward-facing branches were bridged using a combination of balloon-expandable and self-expandable stents. One patient (5.9%) experienced a renal bleeding complication requiring embolization. There were no cases of primary stent occlusion or dislocation. At a mean follow-up of 14 months, one asymptomatic occlusion of an upward-facing branch was detected in computed tomography angiography. No further upward-facing branch-related complications occurred, and 1-year follow-up was available in 41.2% of patients. Conclusions: In our single-center study including 17 patients, upward-facing branches in BEVAR demonstrate high technical success and a low complication rate, offering a promising alternative to traditional access strategies. These findings support broader adoption in select anatomical scenarios, pending larger comparative studies and longer-term data collection.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。