Safe temperature range for intraoperative and early postoperative continuous hyperthermic intraperitoneal perfusion in a swine model of experimental distal gastrectomy with Billroth II reconstruction

在猪远端胃切除联合毕氏II式重建模型中,术中及术后早期持续性腹腔内热灌注的安全温度范围

阅读:3

Abstract

BACKGROUND: The current study sought to investigate the safety of intraoperative and early postoperative continuous hyperthermic intraperitoneal perfusion (IEPCHIP) at different temperatures in a swine model of experimental distal gastrectomy with Billroth II reconstruction. METHODS: Thirty pigs were randomly divided into 5 groups. Two groups were used as the control groups (groups A1 and A2), and 3 groups were used as the perfusion groups (groups B, C and D). Pigs in group A1 received distal gastrectomy with Billroth II reconstruction only. Pigs in groups A2, B, C and D received the same surgery as group A1, followed by IEPCHIP at 37 ± 0.5°C, 42.5 ± 0.5°C, 43.5 ± 0.5°C or 44.5 ± 0.5°C, respectively. The perfusion time was assessed for each pig in group A2 as well as in the perfusion groups, and the perfusions were performed twice for each group. The first perfusion was conducted intraoperatively, and the second perfusion was initiated 1 day after surgery. Data concerning vital signs and hepatic and renal function were collected. Parameters concerning anastomotic healing, the pathology of the anastomotic tissue and abdominal adhesion were compared. RESULTS: The vital signs and hepatic and renal functions of the pigs in groups A1, A2, B and C were not significantly affected by this procedure. In contrast, the vital signs and hepatic and renal functions of the pigs in group D were significantly affected. Compared to the pigs in groups A1, A2 or B, the anastomotic bursting pressure, breaking strength and hydroxyproline content in group C and D pigs were significantly lower. No significant differences were observed in these parameters between groups A1, A2 and B. Abdominal adhesion was more severe in group D pigs. Collagen deposition in group A1, A2 and B pigs was dense in the anastomosis, and inflammatory cell infiltration was observed in group D. CONCLUSIONS: IEPCHIP at 42.5 ± 0.5°C was safe and caused minimal impairments. However, anastomotic healing was affected by perfusion at 43.5 ± 0.5°C and 44.5 ± 0.5°C, and abdominal adhesion was most severe in the group D animals, which were perfused at 44.5 ± 0.5°C.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。