Comparison of single shot and multishot diffusion-weighted imaging in 5-T magnetic resonance imaging for brain disease diagnosis

5T磁共振成像中单次激发和多次激发弥散加权成像在脑疾病诊断中的比较

阅读:1

Abstract

BACKGROUND: Diffusion-weighted imaging (DWI) with single-shot echo-planar imaging (ssEPI) is a valuable tool for detecting acute brain lesions but does suffer from image distortions. Multishot echo-planar imaging (msEPI) is a technique for reducing such distortions. This study aimed to compare the image quality and diagnostic efficacy of ssEPI- and msEPI-DWI at 5.0 T for brain disease detection. METHODS: This study retrospectively reviewed images of 107 consecutive patients with suspected brain diseases who underwent ssEPI- and msEPI-DWI at 5.0 T at the First Affiliated Hospital of University of Science and Technology of China from August 2023 to September 2023. Two radiologists independently graded image quality and measured the image distortion. Signal-to-noise ratio, contrast-to-noise ratio, and apparent diffusion coefficient (ADC) were calculated and compared between ssEPI- and msEPI-DWI. Image quality scores were compared using the Wilcoxon test and other continuous variables by the paired t-test. The diagnostic accuracy of ADC values in distinguishing lesions from normal-appearing tissues was measured with the area under the curve (AUC). RESULTS: Image quality evaluation and distortion analysis revealed that msEPI-DWI significantly outperformed ssEPI-DWI (two-sided P<0.001). No significant difference was observed in signal-to-noise ratio, contrast-to-noise ratio, or ADC values between msEPI- and ssEPI-DWI (two-sided P≥0.601). The ADC values of msEPI- and ssEPI-DWI showed strong correlations for both lesions (r=0.97) and contralateral normal tissues (r=0.91) (two-sided P<0.001). Compared to those of the contralateral white matter, ADC values of low-grade gliomas (LGGs) were significantly higher [ssEPI-DWI: 1,119.9±273.1 vs. 805.1±73.9; msEPI-DWI: 1,196.2±355.6 vs. 757.3±98.0 (unit: ×10(-6) mm(2)/s)], while the ADC values of acute cerebral infarction (ACI) lesions were significantly lower [ssEPI-DWI: 603.9±273.2 vs. 888.9±212.0; msEPI-DWI: 538.0±281.2 vs. 905.0±188.9 (unit: ×10(-6) mm(2)/s)] (two-sided P≤0.003). The AUCs for detecting LGGs were excellent for both ssEPI-DWI [AUC =0.934; 95% confidence interval (CI): 0.84-1.00] and msEPI-DWI (AUC =0.944; 95% CI: 0.86-1.00) (two-sided P<0.001; two-sided DeLong test: P=0.833). CONCLUSIONS: As compared to ssEPI-DWI, msEPI-DWI, when performed at 5.0 T, demonstrated superior image quality and less anatomical distortion in a wide spectrum of brain diseases and showed promising diagnostic performance for LGGs and ACI. In the future, msEPI-DWI at 5.0 T could become clinically routine in the diagnosis and grading of brain disorders.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。