Effect of body contour changes on the setup and dosimetric accuracy of radiotherapy after cervical cancer surgery

宫颈癌手术后体型变化对放射治疗设置和剂量学精度的影响

阅读:1

Abstract

PURPOSE: The body contour of patients with cervical cancer is prone to change between radiotherapy sessions. This study aimed to investigate the effect of body contour changes on the setup and dosimetric accuracy of radiotherapy. METHODS: 15 patients with cervical cancer after surgery were randomly selected for retrospective analysis. The body contours on the once-per-week cone-beam computed tomography (CBCT) were registered to the planning CT (pCT) for subsequent evaluation. A body contour conformity index (CI(body)) was defined to quantify the variation of body changes. The body volume measured by CBCT was collected, and its relative difference in reference with the first CBCT was calculated and denoted by ΔV(n). The relative setup errors, denoted by ΔSE(LR), ΔSE(AP), ΔSE(SI), and ΔSE(vec) for left-right, anterior-posterior, superior-inferior, and vectorial shifts, respectively, were defined as the difference in measured setup errors between the reference and following CBCTs. The planned dose was calculated on the basis of virtual CT generated from CBCT and pCT by altering the CT body contour to fit the body on CBCT without deformable registration. The correlations between body contour changes and relative setup errors as well as dosimetric parameters were evaluated using Spearman's correlation coefficient r(s) . RESULTS: CI(body) was found to be negatively correlated with the superior-inferior and vectorial relative setup errors ΔSE(SI) (r(s) = -0.448, p = 0.001) and ΔSE(vec) (r(s) = -0.387, p = 0.002), and no significant correlation was found between relative setup errors and ΔV(n). Moreover, ΔV(n) was negatively correlated with ΔD(2) (r(s) = -0.829, p < 0.001), ΔD(98) (r(s) = -0.797, p < 0.001), and ΔTV(PIV) (r(s) = -0.819, p < 0.001). ΔD(2), ΔD(98), and ΔTV(PIV) were negatively correlated with ΔV(n) (p < 0.005). No correlation was found for other examined dosimetric parameters. CONCLUSION: The body contour change of patients could be associated with the setup variability. The effect of body contour changes on dose distribution is minimal. The extent of body change could be used as a metric for radiation therapists to estimate the setup errors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。