Quantitative Evaluation of Carotid Artery Stenosis by Multi-VENC 4D Flow MRI: Incorporating Turbulent Kinetic Energy for Clinical Validity

利用多通道4D流磁共振成像技术对颈动脉狭窄进行定量评估:结合湍动能提高临床有效性

阅读:1

Abstract

BACKGROUND: Cervical internal carotid artery stenosis (ICS) is a recognized risk factor for ischemic stroke, yet morphological severity alone may not fully reflect hemodynamic alterations. Turbulent kinetic energy (TKE), derived from multi-velocity-encoding (multi-VENC) four-dimensional (4D) flow MRI, may provide a robust marker for ICS assessment, though its utility in carotid arteries remains underexplored. PURPOSE: To investigate the reproducibility of TKE measurement and to assess correlations with MR angiography (MRA)-derived stenosis, black blood T1-weighted imaging (T1BB)-derived plaque scale, and ultrasound parameters. STUDY TYPE: Prospective. POPULATION: Twenty-three patients (6 [26%] female; median age: 72 years, IQR: 60-80) with suspected ICS based on cerebrovascular symptoms or screening carotid ultrasound. FIELD STRENGTH/SEQUENCE: 3-T, multi-VENC (33-100-300 cm/s) 4D flow MRI of the carotid arteries at 1.0 mm(3) isotropic resolution, using k-space-time principal component analysis (k-t PCA) acceleration, time of flight-MRA (3D gradient-echo), and T1BB (turbo spin echo). ASSESSMENT: Two neuroradiologists measured TKE once per case for interobserver evaluation. TKE was measured in a volume from just proximal to the bifurcation and slightly distal to the ICA stenosis. TKEbeat was defined as the total TKE integrated over the cardiac cycle. Stenosis and plaque features were assessed by MRA and T1BB, respectively. Carotid ultrasound parameters included peak systolic velocity, resistance index, intima-media thickness (IMT), and plaque characteristics. STATISTICAL TESTS: Intraclass correlation coefficient (ICC) and Bland-Altman analyses were used for interobserver agreements. Associations between TKEbeat and conventional parameters were evaluated using Spearman's rank correlation. TKEbeat was compared between subgroups based on stenosis, plaque grade, and vascular risk factors using Mann-Whitney U-tests. Significance threshold: p < 0.05. RESULTS: The ICC was 0.922 for TKEbeat. TKE correlated with stenosis (r = 0.309), plaque scale (r = 0.392), and IMT (r = 0.543). TKEbeat was higher in the stenosis group. DATA CONCLUSION: Multi-VENC 4D flow MRI enables reproducible TKE measurement correlated with carotid stenosis and plaque features. EVIDENCE LEVEL: Level 1. TECHNICAL EFFICACY: Stage 1.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。