Performance evaluation of cefoxitin screen test on two different automated antimicrobial susceptibility test systems: a comparative study

头孢西丁筛选试验在两种不同的自动化抗菌药物敏感性测试系统上的性能评价:一项比较研究

阅读:1

Abstract

Reliable detection of mecA and mecC-mediated beta-lactam resistance using automated antimicrobial susceptibility test systems is critical for patient care. The aim of this study was to compare the performance of the new cefoxitin screen test (oxsf02n) on the Vitek 2 card (Vitek 2) and BD Phoenix PMC-100 Gram-Positive AST Panel (Phoenix) against the reference method for the detection of mecA (and mecC)-mediated beta-lactam resistance. Two hundred fifty clinical fresh and stock Staphylococcus spp. isolates were included. There were 120 mecA-positive, 10 mecC-positive, and 120 mecA and mecC-negative isolates. Cefoxitin screen and oxacillin tests were performed on Vitek 2 and Phoenix and by their respective reference methods (disk diffusion for the cefoxitin screen test and broth microdilution for oxacillin) for all isolates. PCR testing was also performed to confirm the presence of mecA and/or mecC genes. Results from each system were compared to the reference methods. Statistical hypotheses were evaluated both for Vitek 2 compared to the reference methods and Vitek 2 compared to the Phoenix. Compared to the reference method, the Vitek 2 cefoxitin screen test had 100% sensitivity/98% specificity and the Phoenix cefoxitin screen test had 84% sensitivity/100% specificity for the detection of mecA (and mecC)-mediated beta-lactam resistance. When the oxacillin test was combined with the cefoxitin screen for Vitek 2, the sensitivity and specificity were unchanged. However, when the oxacillin and cefoxitin screen tests were combined for the Phoenix, the sensitivity increased to 100% and the specificity remained unchanged (100%). When considering cefoxitin alone, the Vitek 2 screen test showed a higher sensitivity than the Phoenix for the detection of mecA and mecC-mediated beta-lactam resistance. However, currently, both systems use a combination of the cefoxitin and oxacillin tests to interpret the final result, and both reached a high level of performance when cefoxitin and oxacillin results were combined.IMPORTANCEThis research marks the inaugural evaluation of the revamped cefoxitin screen test version in Vitek 2, juxtaposing it against reference methods and a primary competitor BD Phoenix.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。