Effects of different inspiratory muscle warm-up loads on mechanical, physiological and muscle oxygenation responses during high-intensity running and recovery

不同吸气肌热身负荷对高强度跑步及恢复期间机械、生理和肌肉氧合反应的影响

阅读:1

Abstract

Inspiratory muscle warm-up (IMW) has been used as a resource to enhance exercises and sports performance. However, there is a lack of studies in the literature addressing the effects of different IMW loads (especially in combination with a shorter and applicable protocol) on high-intensity running and recovery phase. Thus, this study aimed to investigate the effects of three different IMW loads using a shorter protocol on mechanical, physiological and muscle oxygenation responses during and after high-intensity running exercise. Sixteen physically active men, randomly performed four trials 30 s all-out run, preceded by the shorter IMW protocol (2 × 15 breaths with a 1-min rest interval between sets, accomplished 2 min before the 30 s all-out run). Here, three IMW load conditions were used: 15%, 40%, and 60% of maximal inspiratory pressure (MIP), plus a control session (CON) without the IMW. The force, velocity and running power were measured (1000 Hz). Two near-infrared spectroscopy (NIRS) devices measured (10 Hz) the muscle's oxygenation responses in biceps brachii (BB) and vastus lateralis (VL). Additionally, heart rate (HR) and blood lactate ([Lac]) were also monitored. IMW loads applied with a shorter protocol promoted a significant increase in mean and minimum running power as well as in peak and minimum force compared to CON. In addition, specific IMW loads led to higher values of peak power, mean velocity (60% of MIP) and mean force (40 and 60% of MIP) in relation to CON. Physiological responses (HR and muscles oxygenation) were not modified by any IMW during exercise, as well as HR and [Lac] in the recovery phase. On the other hand, 40% of MIP presented a higher tissue saturation index (TSI) for BB during recovery phase. In conclusion, the use of different loads of IMW may improve the performance of a physically active individual in a 30 s all-out run, as verified by the increased peak, mean and minimum mechanical values, but not in performance assessed second by second. In addition, 40% of the MIP improves TSI of the BB during the recovery phase, which can indicate greater availability of O(2) for lactate clearance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。