Machine Description File-based Monte Carlo Simulation Modeling and its Validation Using Pencil Beam Scanning Proton Therapy Commissioning Data

基于文件的蒙特卡罗模拟建模及其使用笔形束扫描质子治疗调试数据的验证

阅读:1

Abstract

PURPOSE: This study aims to detail the machine description file (MDF)-based modeling and validation of the independent Monte Carlo (MC) dose engine using commissioning beam data of a multi-gantry Proteus Plus proton pencil beam scanning (PBS) machine, also, enhancing the understanding of its operational parameters and clinical applications. MATERIALS AND METHODS: The commissioning of the PBS machine involved measuring key parameters such as integrated depth dose, spot size, and absolute dose using calibrated detectors and ionization chambers. These measurements facilitated the modeling of parameters like energy spread and spot tuning within the RayStation treatment planning system and the tool for particle simulation (TOPAS) Geant4-based MC framework. The validation process employed a MDF containing commissioning beam data, assessing 36 spread-out Bragg peak plans by evaluating range, modulation, distal dose fall-off, and lateral profile characteristics at varying depths. In addition, five patient-specific quality assurance (PSQA) plans were created to evaluate nonhomogeneous fields, following American Association of Physicists in Medicine TG report 185 guidelines. RESULTS: The validation results indicated strong agreement between modeled and measured data, with acceptable comparisons observed between RayStation and TOPAS outputs for homogeneous fields. Nonhomogeneous PSQA results demonstrated that over 95% of cases met the gamma passing criteria of 3%/3 mm. Furthermore, assessments of water equivalent thickness in heterogeneous tissues - such as muscle, fat, bone, and liver - showed discrepancies within 0.5% of the range uncertainty, confirming the accuracy of the modeling approach. CONCLUSION: The MDF-based modeling and validation process is a robust and practical approach for clinical environments, effectively supporting proton therapy research and ensuring quality assurance in treatment planning. The methodologies developed in this study provide valuable insights and tools for researchers utilizing TOPAS MC as a clinical research instrument, paving the way for advancements in proton therapy techniques and patient-specific treatment plans.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。