Are we overestimating proton minibeam therapy effectiveness through physical dose metrics?

我们是否通过物理剂量指标高估了质子微束疗法的有效性?

阅读:1

Abstract

PURPOSE: The conventional implementation of proton spatially fractionated radiotherapy (SFRT) uses physical collimators with millimeter apertures to generate minibeams, creating alternating regions of high-dose peaks and low-dose valleys. Current evaluation of SFRT effectiveness predominantly relies on physical quantities, particularly the peak-to-valley dose ratio (PVDR). While high PVDR and low valley doses have been correlated with improved normal tissue sparing, this physical metric-based approach provides an incomplete picture of the treatment's biological impact. In this work, we aim to quantify biological dose for proton minibeams created using physical collimators and critically evaluate the adequacy of physical (PVDR(PHYS)) as compared to biologically weighted PVDR (PVDR(BIOL)). METHODS: Monte Carlo simulations using TOPAS were performed to model proton minibeam arrangements with 70 and 150 MeV monoenergetic beams, as well as a Spread-Out Bragg Peak (SOBP) configuration to represent clinically relevant dose delivery. We investigated the impact of multiple collimator configurations on PVDR: collimator thickness (6.35 cm), hole diameter (1-3 mm), center-to-center (c-t-c) distances (2, 3, 4 mm for 1 mm hole, 4, 6, 8 mm for 2 mm hole) and air gaps (5, 10, and 15 cm) between the collimator and water phantom. For each configuration, 3D dose and dose-averaged LET (LET(d)) distributions were scored in water phantom, which were subsequently used for RBE calculation using the McNamara model with α/β ratios of 3 or 10 Gy. RESULTS: Our comprehensive analysis revealed significant differences between physical and biological PVDR metrics across various configurations. For both 70 and 150 MeV beams, PVDR(BIOL) was consistently lower than PVDR(PHYS) by 1-25% and 1-21%, respectively, with the most pronounced differences observed at shallow depths, smaller air gaps with larger hole diameter and c-t-c distances. Similar reductions (3.9%-26.5%) in PVDR(BIOL) were observed for the SOBP configuration, with the specific pattern depending on the energy composition and weighting of constituent layers. CONCLUSIONS: The significant variations between PVDR(PHYS) and PVDR(BIOL) across different beam energies, depths, and collimator configurations demonstrate that conventional PVDR calculations based solely on physical dose may not fully represent the biological impact of proton SFRT. These findings highlight the importance of incorporating radiobiological considerations when evaluating and optimizing proton minibeam therapy, potentially leading to more biologically informed treatment planning approaches.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。