Methods
Lysine 2-hydroxyisobutyrylation was examined using immunoblotting and immunofluorescence assays using a previously qualified pan anti-lysine 2-hydroxyisobutyrylation antibody. The immunofluorescence assay was imaged using super-resolution structured illumination microscopy. Sperm viability was examined by using the eosin staining method, and sperm motility parameters were assessed by computer-assisted sperm analysis. Sperm penetration ability was determined by evaluating the ability of the sperm to penetrate a 1% (w/v) methylcellulose solution. The level of intracellular adenosine triphosphate (ATP) was detected using a rapid bioluminescent ATP assay kit. Main