Cell Count Differentials by Cytomorphology and Next-Generation Flow Cytometry in Bone Marrow Aspirate: An Evidence-Based Approach

基于细胞形态学和新一代流式细胞术的骨髓穿刺液细胞计数分类:循证方法

阅读:2

Abstract

Despite a lack of evidence, a bone marrow aspirate differential of 500 cells is commonly used in the clinical setting. We aimed to test the performance of 200-cell counts for daily hematological workup. In total, 660 consecutive samples were analyzed recording differentials at 200 and 500 cells. Additionally, immunophenotype results and preanalytical issues were also evaluated. Clinical and statistical differences between both cutoffs and both methods were checked. An independent control group of 122 patients was included. All comparisons between both cutoffs and both methods for all relevant types of cells did not show statistically significant differences. No significant diagnostic discrepancies were demonstrated in the contingency table analysis. This is a real-life study, and some limitations may be pointed out, such as a different sample sizes according to the type of cell in the immunophenotype analysis, the lack of standardization of some preanalytical events, and the relatively small sample size of the control group. The comparisons of differentials by morphology on 200 and 500 cells, as well as by morphology (both cutoffs) and by immunophenotype, are equivalent from the clinical and statistical point of view. The preanalytical issues play a critical role in the assessment of bone marrow aspirate samples.