Enrichment-free analysis of anionic micropollutants in the sub-ppb range in drinking water by capillary electrophoresis-high resolution mass spectrometry

毛细管电泳-高分辨质谱法非富集分析饮用水中亚 ppb 级阴离子微污染物

阅读:9
作者:Oliver Höcker, Tobias Bader, Torsten C Schmidt, Wolfgang Schulz, Christian Neusüß

Abstract

Reversed-phase liquid chromatography (RPLC) used for water analysis is not ideal for the analysis of highly polar and ionic contaminants because of low retention. Capillary electrophoresis (CE), on the other hand, is perfectly suited for the separation of ionic compounds but rarely applied in environmental analysis due to the weak concentration sensitivity when coupled to mass spectrometry (MS). However, novel interface designs and MS technology strongly improve the sensitivity. Here, a method is presented enabling the screening of anionic micropollutants in drinking water without sample pretreatment by coupling of CE to an Orbitrap mass spectrometer by a nanoflow sheath liquid interface. Targeted analysis of halogenated acetic acids, trifluoromethanesulfonic acid, and perfluorooctanoic and perfluorooctanesulfonic acid was conducted in drinking water samples which were chlorinated for disinfection. A bare fused silica capillary with an optimized background electrolyte (BGE) for separation consisting of 10% acetic acid with 10% isopropanol with large volume sample injection and optimized interface parameters offer limits of quantification in the range of < 0.1 to 0.5 μg/L with good linearity (R2 > 0.993) and repeatability (14% standard deviation in area). Concentrations of the target analytes ranged from 0.1 to 6.2 μg/L in the water samples. Masses corresponding to halogenated methanesulfonic acids have been found as suspects and were subsequently verified by standards. Mono-, dichloro-, and bromochloro methanesulfonic acid were quantified in a range of 0.2 to 3.6 μg/L. Furthermore, five sulfonic acids, four organosulfates, and the artificial sweeteners acesulfame and cyclamate as well as inorganics such as halides, halogenates, phosphate, and sulfate could be determined as suspects among more than 300 features in a non-targeted screening. Overall, this approach demonstrates the great potential of CE-nanoESI-MS for the screening of ionic contaminants in environmental samples, complementary to chromatographic approaches.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。