Minimally Important Difference of the 20-m 6-Minute Walk Test in Individuals With COPD

慢性阻塞性肺病患者20米6分钟步行试验的最小重要差异

阅读:1

Abstract

BACKGROUND: The 20-m 6-min-walk test (6MWT20) is a valid, reliable alternative for functional capacity assessment; however, its responsiveness and minimally important difference (MID) have yet to be investigated. The aim of this study was to assess the responsiveness and MID of the 6MWT20 in individuals with COPD. METHODS: Fifty-three subjects completed the study from August 2011-March 2020. The following were assessed: lung function, activities of daily living (ADLs), functional capacity 6MWT20, dyspnea, health status, quality of life, and limitations in ADLs. The primary outcome was the 6MWT20 distance. RESULTS: The study demonstrated that the 6MWT20 is responsive to pulmonary rehabilitation (PR), with an average improvement of 39 ± 36.3 m (P < .001) and an effect size of 1.07. The learning effect declined to 1.45% after PR, with an intraclass correlation coefficient of 0.99 (95% CI 0.98-0.99). The receiver operating characteristic curve indicated a cutoff point of 20 m for the MID of the 6MWT20 based on the MIDs for the modified St George Respiratory Questionnaire (sensitivity 87%, specificity 69%, area under the curve 0.80 [95% CI 0.66-0.90], P < .001, Youden index 0.56) and the number of steps (sensitivity 92%, specificity 73%, area under the curve 0.83 [95% CI 0.70-0.92], P < .01, Youden index 0.56). CONCLUSIONS: The 6MWT20 is responsive to PR, and the MID for the test is 20 m (17-47 m).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。