Enhanced Aerosol Delivery During High-Flow Nasal Cannula Therapy

高流量鼻导管治疗期间增强气溶胶输送

阅读:1

Abstract

BACKGROUND: Aerosolized drug delivery via high-flow nasal cannula (HFNC) decreases as gas flow is increased. To improve aerosol delivery, breath-enhanced jet nebulizer may increase aerosol output. This study tested that hypothesis and compared breath-enhanced jet nebulizer to vibrating mesh nebulizer technology. METHODS: First, in an isolated circuit, breath-enhanced jet nebulizer and vibrating mesh nebulizer aerosol outputs were measured during simulated HFNC by using infused saline solution at rates of 5-60 mL/h. Limits were defined when nebulizer filling was detected. The devices were then tested by using (99m)Tc/saline solution to measure maximum rates of aerosol production. After the output experiments, drug delivery was measured in vitro by using a model that consisted of an HFNC circuit interfaced to a realistic 3-dimensional printed head. The (99m)Tc/saline solution was infused at rates of 5 to 60 mL/h for the breath-enhanced jet nebulizer and 5 to 20 mL/h for the vibrating mesh nebulizer with HFNC gas flows of 10 to 60 L/min. Aerosol delivery to the trachea was measured by using a shielded ratemeter, which defined the rate of drug delivery (µg NaCl/min). RESULTS: With increasing gas flow, breath-enhanced jet nebulizer output increased to a maximum of 50 mL/h, the vibrating mesh nebulizer maximum was 12 mL/h. At HFNC gas flow of 60 L/min, breath-enhanced jet nebulizer delivered 3.16 to 316.8 µg NaCl/min, the vibrating mesh nebulizer delivered 23.5 to 61.7 µg NaCl/min. For infusion pump flows of 5 to 12 mL/h, the rate of drug delivery was independent of nebulizer type (P = .19) and dependent on infusion pump flow (P < .001) and gas flow (P < .001). CONCLUSIONS: Increasing gas flow increased breath-enhanced jet nebulizer output, which demonstrated the effects of breath enhancement. At 60 L/min, breath enhanced jet nebulizer delivered up to 5 times more aerosol compared with conventional vibrating mesh nebulizer technology. Breath-enhanced jet nebulizer delivered a wide range of dose rates at all high flows. In patients who are critically ill, breath-enhanced jet nebulizer technology may allow titration of bedside dosing based on clinical response by simple adjustment of the infusion rate.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。