Clinical Impact of an Electronic Dashboard and Alert System for Sedation Minimization and Ventilator Liberation: A Before-After Study

电子仪表盘和警报系统在减少镇静和脱离呼吸机方面的临床影响:一项前后对照研究

阅读:1

Abstract

Sedation minimization and ventilator liberation protocols improve outcomes but are challenging to implement. We sought to demonstrate proof-of-concept and impact of an electronic application promoting sedation minimization and ventilator liberation. DESIGN: Multi-ICU proof-of-concept study and a single ICU before-after study. SETTING: University hospital ICUs. PATIENTS: Adult patients receiving mechanical ventilation. INTERVENTIONS: An automated application consisting of 1) a web-based dashboard with real-time data on spontaneous breathing trial readiness, sedation depth, sedative infusions, and nudges to wean sedation and ventilatory support and 2) text-message alerts once patients met criteria for a spontaneous breathing trial and spontaneous awakening trial. Pre-intervention, sedation minimization, and ventilator liberation were reviewed daily during a multidisciplinary huddle. Post-intervention, the dashboard was used during the multidisciplinary huddle, throughout the day by respiratory therapists, and text alerts were sent to bedside providers. MEASUREMENTS AND MAIN RESULTS: We enrolled 115 subjects in the proof-of-concept study. Spontaneous breathing trial alerts were accurate (98.3%), usually sent while patients were receiving mandatory ventilation (88.5%), and 61.9% of patients received concurrent spontaneous awakening trial alerts. We enrolled 457 subjects in the before-after study, 221 pre-intervention and 236 post-intervention. After implementation, patients were 28% more likely to be extubated (hazard ratio, 1.28; 95% CI, 1.01-1.63; p = 0.042) and 31% more likely to be discharged from the ICU (hazard ratio, 1.31; 95% CI, 1.03-1.67; p = 0.027) at any time point. After implementation, the median duration of mechanical ventilation was 2.20 days (95% CI, 0.09-4.31 d; p = 0.042) shorter and the median ICU length of stay was 2.65 days (95% CI, 0.13-5.16 d; p = 0.040) shorter, compared with the expected durations without the application. CONCLUSIONS: Implementation of an electronic dashboard and alert system promoting sedation minimization and ventilator liberation was associated with reductions in the duration of mechanical ventilation and ICU length of stay.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。