How lapse and slip errors influence head-of-bed angle compliance rates as measured by a portable, wireless data collection system

利用便携式无线数据采集系统测量床头角度调整依从率时,失误和滑移误差如何影响床头角度调整依从率。

阅读:1

Abstract

The recommended protocols to prevent ventilator-associated pneumonia include keeping ventilated patients' head and upper body elevated to an angle between 30 and 45 degrees. These recommendations are largely based on a study that has been difficult to replicate, because studies that have attempted to replicate the original conditions have failed to achieve the necessary bed angles consistently. This work suggests the possibility that two specific types of human error, slips and lapses, contribute to non-compliant bed angles. A novel device provided 83,655 samples of bed angles over a period of 1579 hours. The bed angle was out of compliance 64.2% of the time analyzed. Slips, the accident of raising the bed to an angle slightly less than the desired angle, accounted for most of the out-of-compliance measurements, or 55.9% of the time analyzed. It appears that stochastic variation in the bed adjustments results in the bed being out of compliance. Interventions should be investigated such as increasing the target angle and providing feedback at the moment the bed is raised to close to, but less than, the target angle.