Enabling the design of surgical instruments for under-resourced patients through metal additive manufacturing: ulnar shortening osteotomy as an example

利用金属增材制造技术为资源匮乏的患者设计手术器械:以尺骨短缩截骨术为例

阅读:2

Abstract

BACKGROUND: Ulnar shortening osteotomy (USO) has demonstrated good outcomes for patients with ulnar impaction syndrome. To minimize complications such as non-union, precise osteotomy and firm fixation are warranted. Despite various ulnar shortening systems have been developed, current technology does not meet all needs. A considerable portion of patients could not afford those designated USO systems. To tackle this challenge, our team reported successful results in standardized free-hand predrilled USO technique. However, it is still technical demanding and requires sufficient experience and confidence to excel. Therefore, our team designed an ulnar shortening system based on our free-hand technique principle, using metal additive manufacturing technology. The goal of this study is to describe the development process and report the performance of the system. METHODS: Utilizing metal additive manufacturing technology, our team developed an ulnar shortening system that requires minimal exposure, facilitates precise cutting, and allows for the easy placement of a 3.5 mm dynamic compression plate, available to patients at zero out-of-pocket cost. For performance testing, two surgeons with different levels of experience in ulnar shortening procedures were included: one fellow-trained hand and wrist surgeon and one senior resident. They performed ulnar shortening osteotomy (USO) using both the free-hand technique and the USO system-assisted technique on ulna sawbones, repeating each method three times. The recorded parameters included time-to-complete-osteotomy, total procedure time, chip diameter, shortening length, maximum residual gap, and deviation angle. RESULTS: For the hand and wrist fellow, with the USO system, the time-to-complete osteotomy was significantly reduced. (468.7 ± 63.6 to 260.0 ± 5 s, p < 0.05). Despite the preop goal was shortening 3 mm, the average shortening length was significantly larger in the free-hand group (5 ± 0.1; 3.2 ± 0.2 mm, p < 0.05). Both maximum residual gap and deviation angle reported no statistical difference between the two techniques for the hand surgeon. As for the senior resident, the maximum residual gap was significantly reduced, using the USO system (2.9 ± 0.8; 0.4 ± 0.4 mm, p = 0.02). Between two surgeons, significant larger maximum residual gap and deviation angle were noted on the senior resident doctor, in the free-hand technique group, but not in the USO system group. CONCLUSION: The developed USO system may serve as a valuable tool, aiding in reliable and precise cutting as well as fixation for patients undergoing ulnar shortening osteotomy with a 3.5 mm dynamic compression plate, even for less experienced surgeons. The entire process, from concept generation and sketching to creating the CAD file and final production, serves as a translatable reference for other surgical scenarios.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。