Evaluating Optical Quality of a New Hydrophilic Enhanced Monofocal Intraocular Lens and Comparison to the Monofocal Counterpart: An Optical Bench Analysis

新型亲水性增强型单焦点人工晶状体的光学质量评价及其与同类单焦点人工晶状体的比较:光学平台分析

阅读:1

Abstract

INTRODUCTION: The aim of the study was to analyze the optical properties of a new hydrophilic enhanced monofocal intraocular lens (IOL) using optical bench analysis and compare it with its monofocal counterpart. METHODS: This laboratory study investigates the enhanced monofocal intraocular lens (L-333) and the monofocal counterpart (L-313) IOL by Teleon Surgical, Spankeren, Netherlands on the optical bench, using OptiSpheric IOL PRO2 (Trioptics, Germany) in order to assess the optical quality according to ISO 11979 with ISO-2 Cornea. IOLs (power 22.0 D) were evaluated regarding through frequency modulation transfer function (MTF), Strehl ratio (SR), and through focus MTF at 50 lp/mm using a 3.0-mm and a 4.5-mm aperture. Tilt and decentration were applied. In addition, wavefront measurements were obtained using WaveMaster® IOL 2 device (Trioptics, Germany) and analyzed. RESULTS: Centered: The MTF (mean) at 50 lp/mm (L-333/L-313) with 3.0 mm aperture was 0.606/0.724 and with 4.5 mm aperture 0.330/0.409. The SR (mean) with 3.0 mm aperture was 0.586/0.809 and with 4.5 mm aperture 0.330/0.348. Decentered by 1 mm: The MTF (mean) at 50 lp/mm (L-333/L-313) with 3.0 mm aperture was 0.485/0.705 and with 4.5 mm aperture 0.255/0.374. The SR (mean) with 3.0 mm aperture was 0.457/0.739 and with 4.5 mm aperture 0.185/0.268. Tilted by 5 degrees: The MTF (mean) at 50 lp/mm (L-333/L-313) with 3.0 mm aperture was 0.577/0.657 and with 4.5 mm aperture 0.345/0.336. The SR (mean) with 3.0 mm aperture was 0.583/0.702 and with 4.5 mm aperture 0.269/0.237. In through focus MTF and aperture of 3.0 mm, the L-333 showed a peak of 0.41 with some enlarged depth of power of about 2 D. For the aperture of 4.5 mm, the MTF values of L-313 and L-333 were slightly reduced; L-333 showed an MTF peak of 0.23 and some reduced depth of power of about 1.5 D. Wavefront measurements showed no major aberrations for the L-313, while a combination of moderate increase in Z 4-0 and Z 6-0 with opposite sign was revealed for the L-333. CONCLUSION: The enhanced monofocal Lentis Quantum (L-333) produces some enlarged depth of focus by combining spherical aberration of different order and opposite sign. The Lentis Quantum performs very well in comparison to the aspherical monofocal counterpart owing to its optical design. Results with large apertures were sufficient too, suggesting that  the lens is a good option in eyes with a wide pupil and thus in refractive surgeries of young patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。