Chest Wall to Heart Distance Reproducibility in Postoperative Deep Inspiration Breath-Hold Radiotherapy for Left-Sided Breast Cancer Using an Anzai Laser Sensor With Visual Feedback

使用安斋激光传感器结合视觉反馈,评估左侧乳腺癌术后深吸气屏气放射治疗中胸壁至心脏距离的重复性

阅读:1

Abstract

Background Left-sided breast cancer radiotherapy may increase the risk of cardiovascular death due to possible heart irradiation. The reproducibility of the chest wall to heart distance in deep inspiration breath-hold (DIBH) was studied using a laser sensor with visual feedback. Methodology A total of 10 consecutive postoperative left-sided breast cancer cases receiving DIBH radiotherapy between December 2022 and September 2023 were retrospectively investigated. The prescribed dose was 50 Gy in 25 fractions. An Anzai respiratory gating system, AZ-733VI (Anzai, Tokyo, Japan), was employed that has a laser displacement sensor and a visual feedback device. An Elekta linac with a cone-beam CT unit, Axesse (Elekta AB, Stockholm, Sweden), was used in this study. The interfractional changes in the chest wall to heart distance among 25 fractions were analyzed for each of the 10 patients in each coordinate axis. In addition, the median with the 95% confidence interval (CI) and interquartile range (IQR) for all 250 fractions were calculated in each axis to assess the reproducibility of our DIBH technique. Results The medians of the interfractional changes in the chest wall to heart distance in each of the 10 patients ranged from -2 mm to 3 mm, -1 mm to 3 mm, and -2 mm to 1 mm in the lateral (X), superior-inferior (Y), and anterior-posterior (Z) directions, respectively. For all 10 cases, the medians were 1 mm (95% CI = 0.72 to 1.28 mm) in X, 1 mm (95% CI = 0.76 to 1.24 mm) in Y, and 0 mm (95% CI = -0.20 to 0.20 mm) in Z directions, whereas the IQRs were 4 mm in X, 2 mm in Y and 2 mm in Z directions. The measured IQRs were two to three times smaller than those shown in a previous report without visual feedback, suggesting a clinical advantage of the visual feedback in DIBH for left-sided breast cancer radiotherapy. The DIBH solution shown in this study required approximately 10 minutes from room-in to room-out, thereby not reducing the daily number of patients. Conclusions Our DIBH approach with visual feedback achieved better distance reproducibility between the chest wall and heart by a factor of two to three in terms of IQR compared to the previously reported data without visual feedback. Patient throughput was also favorable. To our knowledge, this is the first report demonstrating the chest wall to heart distance reproducibility in DIBH with visual feedback.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。