Simple method for detecting idiopathic interstitial pneumonias by measuring vertical lung length on chest X-ray

通过胸部X光片测量肺垂直长度来检测特发性间质性肺炎的简便方法

阅读:1

Abstract

Detection of idiopathic interstitial pneumonias (IIPs) on chest X-ray is difficult for non-specialist physicians, especially in patients with mild IIPs. The current study aimed to evaluate the usefulness of a simple method for detecting IIPs by measuring vertical lung length (VLL) in chest X-rays to quantify decreased lung volume. A total of 280 consecutive patients with IIPs were randomly allocated to exploratory and validation cohorts, and 140 controls were selected for each cohort by propensity score-matching. Upper (uVLL; from apex to tracheal carina), lower (lVLL; from carina to costophrenic angle), and total VLL (tVLL; from apex to costophrenic angle), and the l/uVLL ratio were measured on chest X-rays. Patients in the exploratory cohort had significantly decreased uVLL, lVLL, tVLL, and l/uVLL ratio compared with controls (all p < 0.001). Receiver operating characteristic curve analyses demonstrated that lVLL (area under the curve [AUC] 0.86, sensitivity 0.65, specificity 0.92), tVLL (AUC 0.83, sensitivity 0.75, specificity 0.80), and l/uVLL ratio (AUC 0.80, sensitivity 0.72, specificity 0.79) had high diagnostic accuracies for IIPs. These results were reproduced in the validation cohort. IIP patients thus have decreased VLLs, and measurements of VLL may thus aid the accurate detection of IIPs.