Performance of a domestic refrigerator in varying ambient temperatures, concentrations of TiO(2) nanolubricants and R600a refrigerant charges

家用冰箱在不同环境温度、TiO₂纳米润滑剂浓度和R600a制冷剂充注量下的性能

阅读:1

Abstract

This study investigates the effect of varying test conditions including ambient temperature (19, 22, and 25 °C), mass charges of R600a refrigerant (40, 50, 60, and 70 g), and concentrations of TiO(2) nanolubricant (0, 0.2 and 0.4 g/L) on the performance of a slightly modified 100g R134a domestic refrigeration system. The investigated parameters include evaporator air temperature, energy consumption, coefficient of performance, and second law efficiency of the system. The results showed that the performance of the refrigeration system at 0.2 and 0.4 g/L concentrations of TiO(2) nanolubricant, improved at optimum ambient temperature and R600a mass charge conditions. At optimum conditions, the evaporator air temperature and energy consumption reduced within the range 5.26 to 26.32 %, and 0.13 to 14.09 % respectively, while the coefficient of performance and second law efficiency increased within the range 0.05 to 16.32 %, and 2.8 to 16 %, respectively. However, at other conditions (non-optimum), the energy consumption and evaporator air temperature were higher and within the range 0.28 to 8.26 %, and 5 to 40 % respectively, while the coefficient of performance and second law efficiency reduced within the range 2.99 to 10.94 %, and 0.55 to 13.43 % respectively. In conclusion, we observed variations in the performance of the refrigerator with varying test conditions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。