Finite Volume Method Modeling of Heat Transfer in Acoustic Enclosure for Machinery

机械声学封闭空间内传热的有限体积法建模

阅读:1

Abstract

This paper deals with the problem of heat accumulation in acoustic enclosures. Increased noise levels at production sites or manufacturing lines force the application of acoustic enclosures. Effective noise reduction due to enclosures often comes with the additional thermal insulation of the device, which in many cases causes a strong increase in the device operation temperature. This paper presents the methodology of thermal phenomena numerical modeling based on the potential influence of acoustic enclosures on the increase in device operation temperature. The proposed model consists of an original acoustic enclosure concept design, and the numerical modeling is based on the computational fluid dynamics FVM (finite volume method) conducted in Ansys Fluent. The research comprised a set of simulations at different air flow rates of 52.5 m(3)/h, 105 m(3)/h, 210 m(3)/h and 420 m(3)/h at the enclosure inlet. The analysis carried out on the basis of flow paths and temperature distribution plots inside the enclosure led to the conclusion that the expected, analytically calculated minimum volumetric flow rate is not sufficient to effectively cool the investigated device to the required temperature of 26 °C, and higher air flow rates should be applied. Simulation results indicated that the numerical tools can be useful in the prediction of the heat exchange process, as well as in the selection of an appropriate source and location of cooling.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。