Development and Validation of a Machine Learning Model to Predict Near-Term Risk of Iatrogenic Hypoglycemia in Hospitalized Patients

开发和验证用于预测住院患者近期医源性低血糖风险的机器学习模型

阅读:1

Abstract

IMPORTANCE: Accurate clinical decision support tools are needed to identify patients at risk for iatrogenic hypoglycemia, a potentially serious adverse event, throughout hospitalization. OBJECTIVE: To predict the risk of iatrogenic hypoglycemia within 24 hours after each blood glucose (BG) measurement during hospitalization using a machine learning model. DESIGN, SETTING, AND PARTICIPANTS: This retrospective cohort study, conducted at 5 hospitals within the Johns Hopkins Health System, included 54 978 admissions of 35 147 inpatients who had at least 4 BG measurements and received at least 1 U of insulin during hospitalization between December 1, 2014, and July 31, 2018. Data from the largest hospital were split into a 70% training set and 30% test set. A stochastic gradient boosting machine learning model was developed using the training set and validated on internal and external validation. EXPOSURES: A total of 43 clinical predictors of iatrogenic hypoglycemia were extracted from the electronic medical record, including demographic characteristics, diagnoses, procedures, laboratory data, medications, orders, anthropomorphometric data, and vital signs. MAIN OUTCOMES AND MEASURES: Iatrogenic hypoglycemia was defined as a BG measurement less than or equal to 70 mg/dL occurring within the pharmacologic duration of action of administered insulin, sulfonylurea, or meglitinide. RESULTS: This cohort study included 54 978 admissions (35 147 inpatients; median [interquartile range] age, 66.0 [56.0-75.0] years; 27 781 [50.5%] male; 30 429 [55.3%] White) from 5 hospitals. Of 1 612 425 index BG measurements, 50 354 (3.1%) were followed by iatrogenic hypoglycemia in the subsequent 24 hours. On internal validation, the model achieved a C statistic of 0.90 (95% CI, 0.89-0.90), a positive predictive value of 0.09 (95% CI, 0.08-0.09), a positive likelihood ratio of 4.67 (95% CI, 4.59-4.74), a negative predictive value of 1.00 (95% CI, 1.00-1.00), and a negative likelihood ratio of 0.22 (95% CI, 0.21-0.23). On external validation, the model achieved C statistics ranging from 0.86 to 0.88, positive predictive values ranging from 0.12 to 0.13, negative predictive values of 0.99, positive likelihood ratios ranging from 3.09 to 3.89, and negative likelihood ratios ranging from 0.23 to 0.25. Basal insulin dose, coefficient of variation of BG, and previous hypoglycemic episodes were the strongest predictors. CONCLUSIONS AND RELEVANCE: These findings suggest that iatrogenic hypoglycemia can be predicted in a short-term prediction horizon after each BG measurement during hospitalization. Further studies are needed to translate this model into a real-time informatics alert and evaluate its effectiveness in reducing the incidence of inpatient iatrogenic hypoglycemia.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。