Merkel cell carcinoma (MCC) is an aggressive neuroendocrine skin tumor. Currently, 18F-fluoro-deoxy-glucose (18F-FDG) PET/CT is the functional imaging modality of choice. Few data are available on the use of 68Ga-somatostatin analogs. The

Conclusions

Our preliminary data suggest that 18F-FDG and 68Ga-somatostatin analog PET/CT provide good and equivalent diagnostic performance, adding interesting insights into the complex MCC biology. However, these results do not suggest that 18F-FDG PET/CT should be replaced by 68Ga-somatostatin receptor imaging, which should be performed in addition, according to clinical indication, to the perspective of "personalized medicine."

Results

Fifteen patients (12 males, 3 females; median age 73 years; range 41-81 years) with histologically proven MCC (4 with unknown primary lesion) who underwent both 18F-FDG and 68Ga-somatostatin analog PET/CT for staging, re-staging, or treatment response assessment were retrospectively evaluated. Results of both studies were qualitatively analyzed and compared on a patient- and lesion-based analysis, using histology or clinical/radiological follow-up as reference standard for final diagnosis. According to final diagnosis, 8/15 patients had at least one MCC lesion and 7/15 had no evidence of disease. On a patient-based analysis, 18F-FDG and 68Ga-somatostatin analogs correctly classified as positive 8/8 (100% sensitivity) patients and as negative 6/7 (85.7% specificity) and 5/7 (71.4% specificity) patients, respectively, with no significant difference. On a lesion-based analysis, 18F-FDG detected 67/75 lesions (89%) and 68Ga-somatostatin analogs 69/75 (92%), with no significant difference. In four patients with unknown primary MCC, both tracers failed to identify the primary MCC site. Conclusions: Our preliminary data suggest that 18F-FDG and 68Ga-somatostatin analog PET/CT provide good and equivalent diagnostic performance, adding interesting insights into the complex MCC biology. However, these results do not suggest that 18F-FDG PET/CT should be replaced by 68Ga-somatostatin receptor imaging, which should be performed in addition, according to clinical indication, to the perspective of "personalized medicine."

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。