An NGS-assisted diagnostic workflow for culture-independent detection of bloodstream pathogens and prediction of antimicrobial resistances in sepsis

一种基于NGS的诊断工作流程,用于不依赖培养检测血流病原体并预测脓毒症中的抗菌药物耐药性

阅读:2

Abstract

BACKGROUND: Timely and accurate identification of bloodstream pathogens is critical for targeted antimicrobial therapy in sepsis. Conventional blood cultures remain the Standard-of-Care (SoC) for pathogen identification but are limited by low sensitivity and prolonged turnaround times, hampering timely and targeted antimicrobial stewardship. Advances in next-generation sequencing (NGS) offer potential for culture-independent, rapid, and comprehensive detection of pathogens and prediction of antimicrobial resistance. This study evaluated the diagnostic performance of PISTE™ technology, an NGS-based diagnostic workflow combining full-length 16S rRNA gene sequencing and metagenomic analysis for the diagnosis of circulating bacteria in sepsis. METHODS: In this prospective, multicenter, phase IIa proof-of-concept study, adult patients with suspected sepsis were enrolled from four hospitals in Athens, Greece. Blood samples were collected prior to antibiotic initiation and processed using SoC cultures and PISTE platform. PISTE integrates automated DNA purification (KingFisher, Thermo Fisher Scientific), full-length 16S rRNA gene sequencing, metagenomics analysis (SQK-PRB114.24, Oxford Nanopore Technologies), and real-time sequencing using Oxford Nanopore GridION Mk1b device. A dedicated analysis pipeline was developed for accurate pathogen detection and prediction of antimicrobial resistance profiles. The primary endpoint was the diagnostic concordance between PISTE and SoC cultures. RESULTS: A total of 100 patients (median age 79 years, median Charlson's Comorbidity Index 5) were enrolled. Of these, 71 patients met Sepsis-3 criteria. In this subgroup, PISTE showed an overall accuracy of 95.7%, with a sensitivity of 91.7%, specificity of 96.5%, positive predictive value of 84.6%, and negative predictive value of 98.2% compared to SoC. The median time to pathogen identification and Antimicrobial Susceptibility Testing (AST) with PISTE was 12.0 hours, significantly faster than in SoC cultures (30.4 hours, p < 0.0001). Resistance gene profiling showed strong agreement with SoC AST results, particularly for β-lactam and carbapenem resistance. CONCLUSIONS: PISTE technology exhibited high diagnostic accuracy and significantly reduced turnaround time compared to conventional cultures, supporting its potential as a short turnaround time and reliable diagnostic tool for bloodstream infections. Further optimization and validation in larger cohorts are warranted to enhance clinical implementation and improve antimicrobial stewardship in sepsis management.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。