Abstract
OBJECTIVE: The aim of this study was to identify and analyze biosafety risk points in biosafety level 3 (BSL-3) laboratory facilities to bring awareness to the attention of administrative staff, reduce the biosafety risks, and improve the risk management. METHODS: The biosafety risk points in BSL-3 facilities were identified by literature searches and field research methods, and the identified biosafety risk points subsequently analyzed using the fault analysis event tree method. RESULTS & CONCLUSION: Throughout the comprehensive screening and identification of biosafety risk points in BSL-3 laboratory facilities, risk assessments were performed to rank their seriousness. This will help effectively reduce the biosafety risk level of BSL-3 laboratory facilities.