Pulmonary Valve Replacement Using an Intraoperatively Created Trileaflet Autologous Pericardial Valve: A Case Series

采用术中自体三叶式心包瓣膜进行肺动脉瓣置换术:病例系列研究

阅读:1

Abstract

BACKGROUND: Pulmonary valve replacement is inevitable for the majority of patients with long-standing pulmonary regurgitation. The purpose of this study was to describe the experience of employing a novel technique to create an intraoperatively handmade trileaflet pulmonary valve with glutaraldehyde-treated autologous pericardium (the AAA valve). METHODS: This case series study was conducted from September 2018 to March 2021 at Shiraz University of Medical Sciences, Shiraz, Iran. The surgical technique involved harvesting and treating with glutaraldehyde of the pericardium, constructing a trileaflet valve by encapsulating the pericardium within a Dacron tube with a diameter of 22 mm and a length of 20 mm, and implanting it into the pulmonary valve position. RESULTS: The AAA valve was constructed for 10 patients with a mean age of 16.20±5.81 years, seven of whom had undergone surgery for tetralogy of Fallot. The patients' mean follow-up length was 32.30±13.64 months. The AAA valve regurgitation was none to moderate. At the time of follow-up, all patients had AAA valve stenosis that was less than moderate, except for one case. Cardiac magnetic resonance imaging and echocardiography results confirmed mild leaflet motion restriction in the patient with moderate stenosis. The anatomic valve parameters in MRI revealed a mean geometric height, coaptation height, and effective height of 20.23±2.40 mm, 10.42±1.67 mm, and 14.34±2.24 mm, respectively. One patient died from non-cardiac causes. CONCLUSION: The surgical establishment of a native pericardial valve in the pulmonary valve position yielded satisfactory short-term to midterm results and might be considered a viable alternative to the available options.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。