Whole genome mutagenicity evaluation using Hawk-Seq™ demonstrates high inter-laboratory reproducibility and concordance with the transgenic rodent gene mutation assay

使用 Hawk-Seq™ 进行的全基因组诱变性评估显示出高度的实验室间重复性,并且与转基因啮齿动物基因突变试验结果一致。

阅读:1

Abstract

BACKGROUND: Error-corrected next-generation sequencing (ecNGS) enables the sensitive detection of chemically induced mutations. Matsumura et al. reported Hawk-Seq™, an ecNGS method, demonstrating its utility in clarifying mutagenicity both qualitatively and quantitatively. To further promote the adoption of ecNGS-based assays, it is important to evaluate their inter-laboratory transferability and reproducibility. Therefore, we evaluated the inter-laboratory reproducibility of Hawk-Seq™ and its concordance with the transgenic rodent mutation (TGR) assay. RESULTS: The Hawk-Seq™ protocol was successfully transferred from the developer's laboratory (lab A) to two additional laboratories (labs B, C). Whole genomic mutations were analyzed independently using the same genomic DNA samples from the livers of gpt delta mice exposed to benzo[a]pyrene (BP), N-ethyl-N-nitrosourea (ENU), and N-methyl-N-nitrosourea (MNU). In all laboratories, clear dose-dependent increases in base substitution (BS) frequencies were observed, specific to each mutagen (e.g. G:C to T:A for BP). Statistically significant increases in overall mutation frequencies (OMFs) were identified at the same doses across all laboratories, suggesting high reproducibility in mutagenicity assessment. The correlation coefficient (r(2)) of the six types of BS frequencies exceeded 0.97 among the three laboratories for BP- or ENU-exposed samples. Thus, Hawk-Seq™ provides qualitatively and quantitatively reproducible results across laboratories. The OMFs in the Hawk-Seq™ analysis positively correlated (r(2) = 0.64) with gpt mutant frequencies (MFs). The fold induction of OMFs in the Hawk-Seq™ analysis of ENU- and MNU-exposed samples was at least 14.2 and 4.5, respectively, compared to 6.1 and 2.5 for gpt MFs. Meanwhile, the fold induction of OMFs in BP-exposed samples was ≤ 4.6, compared to 8.2 for gpt MFs. These observations suggest that Hawk-Seq™ demonstrates good concordance with the transgenic rodent (TGR) gene mutation assay, whereas the induction of mutation frequency by each mutagen might not directly correspond. CONCLUSIONS: Hawk-Seq™-based whole-genome mutagenicity evaluation demonstrated high inter-laboratory reproducibility and concordance with gpt assay results. Our results contribute to the growing evidence that ecNGS assays provide a suitable, or improved, alternative to the TGR assay.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。