Comparison of EPI distortion correction methods in diffusion tensor MRI using a novel framework

利用一种新框架比较扩散张量磁共振成像中的EPI畸变校正方法

阅读:1

Abstract

Diffusion weighted images (DWIs) are commonly acquired with Echo-planar imaging (EPI). B0 inhomogeneities affect EPI by producing spatially nonlinear image distortions. Several strategies have been proposed to correct EPI distortions including B0 field mapping (B0M) and image registration. In this study, an experimental framework is proposed to evaluation the performance of different EPI distortion correction methods in improving DT-derived quantities. A deformable registration based method with mutual information metric and cubic B-spline modeled constrained deformation field (BSP) is proposed as an alternative when B0 mapping data are not available. BSP method is qualitatively and quantitatively compared to B0M method using the framework. Both methods can successful reduce EPI distortions and significantly improve the quality of DT-derived quantities. Overall, B0M was clearly superior in infratentorial regions including brainstem and cerebellum, as well as in the ventral areas of the temporal lobes while BSP was better in all rostral brain regions.