Using Auto-Segmentation to Reduce Contouring and Dose Inconsistency in Clinical Trials: The Simulated Impact on RTOG 0617

利用自动分割减少临床试验中的轮廓勾画和剂量不一致:对 RTOG 0617 的模拟影响

阅读:1

Abstract

PURPOSE: Contouring inconsistencies are known but understudied in clinical radiation therapy trials. We applied auto-contouring to the Radiation Therapy Oncology Group (RTOG) 0617 dose escalation trial data. We hypothesized that the trial heart doses were higher than reported due to inconsistent and insufficient heart segmentation. We tested our hypothesis by comparing doses between deep-learning (DL) segmented hearts and trial hearts. METHODS AND MATERIALS: The RTOG 0617 data were downloaded from The Cancer Imaging Archive; the 442 patients with trial hearts and dose distributions were included. All hearts were resegmented using our DL pipeline and quality assured to meet the requirements for clinical implementation. Dose (V5%, V30%, and mean heart dose) was compared between the 2 sets of hearts (Wilcoxon signed-rank test). Each dose metric was associated with overall survival (Cox proportional hazards). Lastly, 18 volume similarity metrics were assessed for the hearts and correlated with |Dose(DL) - Dose(RTOG0617)| (linear regression; significance: P ≤ .0028; corrected for 18 tests). RESULTS: Dose metrics were significantly higher for DL hearts compared with trial hearts (eg, mean heart dose: 15 Gy vs 12 Gy; P = 5.8E-16). All 3 DL heart dose metrics were stronger overall survival predictors than those of the trial hearts (median, P = 2.8E-5 vs 2.0E-4). Thirteen similarity metrics explained |Dose(DL) - Dose(RTOG0617)|; the axial distance between the 2 centers of mass was the strongest predictor (CENT(Axial); median, R(2) = 0.47; P = 6.1E-62). CENT(Axial) agreed with the qualitatively identified inconsistencies in the superior direction. The trial's qualitative heart contouring score was not correlated with |Dose(DL) - Dose(RTOG0617)| (median, R(2) = 0.01; P = .02) or with any of the similarity metrics (median, Rs = 0.13 [range, -0.22 to 0.31]). CONCLUSIONS: Using a coherent heart definition, as enabled through our open-source DL algorithm, the trial heart doses in RTOG 0617 were found to be significantly higher than previously reported, which may have led to an even more rapid mortality accumulation. Auto-segmentation is likely to reduce contouring and dose inconsistencies and increase the quality of clinical RT trials.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。