Monolayer Graphene Radiation Sensor with Backend RF Ring Oscillator Transducer

带后端射频环形振荡器换能器的单层石墨烯辐射传感器

阅读:1

Abstract

This paper proposes a new graphene gamma- and beta-radiation sensor with a backend RF ring oscillator transducer employed to convert the change in the graphene resistivity due to ionizing irradiation into a frequency output. The sensor consists of a CVD monolayer of graphene grown on a copper substrate, with an RF ring oscillator readout circuit in which the percentage change in frequency is captured versus the change in radiation dose. The novel integration of the RF oscillator transducer with the graphene monolayer results in high average sensitivity to gamma irradiation up to 3.82 kΩ/kGy, which corresponds to a percentage change in frequency of 7.86% kGy(-1) in response to cumulative gamma irradiation ranging from 0 to 1 kGy. The new approach helps to minimize background environmental effects (e.g., due to light and temperature), leading to an insignificant error in the output change in frequency of the order of 0.46% when operated in light versus dark conditions. The uncertainty in readings due to background light was analyzed, and the error in the resistance was found to be of the order of 1.34 Ω, which confirms the high stability and selectivity of the proposed sensor under different background effects. Furthermore, the evolution of the graphene's lattice defect density due to radiation was observed using Raman spectroscopy and SEM, indicating a lattice defect density of up to 1.780 × 10(11)/cm(2) at 1 kGy gamma radiation, confirming the increase in the graphene resistance and proving the graphene's sensitivity. In contrast, the graphene's defect density in response to beta radiation was 0.683 × 10(11)/cm(2) at 3 kGy beta radiation, which is significantly lower than the gamma effects. This can be attributed to the lower p-doping effect caused by beta irradiation in ambient conditions, compared with that caused by gamma irradiation. Morphological analysis was used to verify the evolution of the microstructural defects caused by ionizing irradiation. The proposed sensor monitors the low-to-medium cumulative range of ionizing radiations ranging from 0 to 1 kGy for gamma radiation and 0 to 9 kGy for beta radiation, with high resolution and selectivity, filling the research gap in the study of graphene-based radiation sensors at low-to-medium ionizing radiation doses. This range is essential for the pharmaceutical and food industries, as it spans the minimum range for affecting human health, causing cancer and DNA damage.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。