Detection and Location of Defects in Externally Bonded FRP Concrete Structures-Comparison of Selected Methods

外部粘结FRP混凝土结构缺陷的检测与定位——几种方法的比较

阅读:1

Abstract

This paper compares three nondestructive methods used to detect and locate defects such as delaminations or voids in externally bonded fiber reinforced polymer (FRP) concrete structures: infrared thermography, ground-penetrating radar, and measurement of acoustic wave velocity. One of the main goals was to check whether it was possible to distinguish overlapping defects. For this purpose, eight concrete samples were made with a bonded carbon fiber reinforced polymer (CFRP) strip with the following dimensions 100 × 100 × 500 mm. Two samples had no defects, four had single defects varying in location (at the edge of the strip or in the centre) simulating delamination or voids in the concrete cover, and the remaining samples had overlapping defects. Both infrared thermography and acoustic wave velocity measurement methods allow the detection of defects/voids in the adhesive layer and a concrete defect (void in the concrete cover). However, ground penetration failed to detect defects in the adhesive layer. Only infrared thermography allows for the differentiation of overlapping defects. On the basis of the conducted research, the methodology, differences, advantages, and limitations of each method were described, along with recommendations based on the authors' experience.