Characterization of Brachycephalic Obstructive Airway Syndrome in Cats Using Barometric Whole-Body Plethysmography

利用气压式全身容积描记法对猫的短头犬阻塞性气道综合征进行表征

阅读:1

Abstract

Objectives: To confirm the utility of barometric whole-body plethysmography (BWBP) as a non-invasive, clinical diagnostic test for brachycephalic obstructive airway syndrome (BOAS) in cats. Methods: Client-owned cats belonging to brachycephalic breeds were enrolled and classified into two clinical severity grades of upper airway obstruction (UAO). Brachycephalic cats with high-grade UAO severity (Brachy-H-UAO) represented those with clinically evident effects on clinical signs or physical examination findings, whereas brachycephalic cats with low-grade UAO severity (Brachy-L-UAO) represented those without clinically evident problems. A group of non-brachycephalic (NB) cats that were respiratory disease-free and with neither a history of cardiac or systemic diseases nor exposure to cigarette smoke was used as the control group. Cats were placed in the BWBP chamber, and breathing signals were obtained after an adaptation period in a quiet and silent environment. The ventilatory variables obtained were respiratory rate (RR; [bpm]), tidal and minute volume per kilogram bodyweight (MV/BW and TV/BW; [mL/kg]), inspiratory (Ti; [s]) and expiratory (Te; [s]) intervals, airway obstruction index enhanced pause (Penh), and peak inspiratory and expiratory flows per kilogram (PIF and PEF; [mL/s/kg]). Results: Forty-three client-owned cats (11 Brachy-H-UAO, 7 Brachy-L-UAO, and 25 NB) were included. Brachycephalic cats (Brachy-H-UAO: 311 mL/kg; Brachy-L-UAO: 253 mL/kg) showed significantly lower median MV/BW than NB cats (503 mL/kg) (p = 0.01). Brachy-H-UAO cats demonstrated significantly higher median PEF/PIF ratios (Brachy-H-UAO: 1.46, minimum-maximum 0.82-2.48; Brachy-L-UAO: 0.76, 0.52-1.11; NB: 0.73, 0.56-1.00) and Penh (Brachy-H-UAO: 2.37, minimum-maximum 0.57-23.82; Brachy-L-UAO: 0.57, 0.27-1.11; NB: 0.53, 0.21-0.68) than Brachy-L-UAO and NB cats (p < 0.001). No significant differences were observed among the three groups for RR, TV/BW, Ti, Te, or Te/Ti. Conclusions and Relevance: Cats affected by BOAS demonstrate impaired ventilatory function, with reduced minute ventilation and a distinctive flow pattern and parameters reflecting limited inspiratory flow and increased upper airway resistance. BWBP can serve as a useful tool to diagnose and characterize the severity of BOAS in cats.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。