Differences in pulmonary function measured by oscillometry between horses with mild-moderate equine asthma and healthy controls

通过振荡法测量轻度至中度马哮喘马匹与健康对照组马匹的肺功能差异

阅读:2

Abstract

BACKGROUND: The diagnosis of mild-moderate equine asthma (MEA) can be confirmed by airway endoscopy, bronchoalveolar lavage fluid (BALf) cytology, and lung function evaluation by indirect pleural pressure measurement. Oscillometry is a promising pulmonary function test method, but its ability to detect subclinical airway obstruction has been questioned. OBJECTIVES: To evaluate the differences in lung function measured by oscillometry between healthy and MEA-affected horses. STUDY DESIGN: Prospective case-control clinical study. METHODS: Thirty-seven horses were divided into healthy and MEA groups, based on history and clinical score; the diagnosis of MEA was confirmed by airway endoscopy and BALf cytology. Horses underwent oscillometry at frequencies ranging from 2 to 6 Hz. Obtained parameters included whole-breath, inspiratory, expiratory, and the difference between inspiratory and expiratory resistance (Rrs) and reactance (Xrs). Differences between oscillometry parameters at different frequencies were evaluated within and between groups by repeated-measures two-way ANOVA and post hoc tests with Bonferroni correction. Frequency dependence was compared between groups by t test. For significant parameters, a receiver operating characteristics curve was designed, cut-off values were identified and their sensitivity and specificity were calculated. Statistical significance was set at p < 0.05. RESULTS: No significant differences in Xrs and Rrs were observed between groups. The frequency dependence of whole-breath and inspiratory Xrs significantly differed between healthy (respectively, -0.03 ± 0.02 and -0.05 ± 0.02 cmH(2)O/L/s) and MEA (-0.1 ± 0.03 and -0.2 ± 0.02 cmH(2)O/L/s) groups (p < 0.05 and p < 0.01). For inspiratory Xrs frequency dependence, a cut-off value of -0.06 cmH(2)O/L/s was identified, with 86.4% (95% CI: 66.7%-95.3%) sensitivity and 66.7% (95% CI: 41.7%-84.8%) specificity. MAIN LIMITATIONS: Sample size, no BALf cytology in some healthy horses. CONCLUSIONS: Oscillometry can represent a useful non-invasive tool for the diagnosis of MEA. Specifically, the evaluation of the frequency dependence of Xrs may be of special interest.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。