Comparison of mathematically arterialised venous blood gas sampling with arterial, capillary, and venous sampling in adult patients with hypercapnic respiratory failure: a single-centre longitudinal cohort study

数学动脉化静脉血气采样与动脉、毛细血管和静脉采样在成人高碳酸血症呼吸衰竭患者中的比较:一项单中心纵向队列研究

阅读:1

Abstract

BACKGROUND: Accurate arterial blood gas (ABG) analysis is essential in the management of patients with hypercapnic respiratory failure, but repeated sampling requires technical expertise and is painful. Missed sampling is common and has a negative impact on patient care. A newer venous to arterial conversion method (v-TAC, Roche) uses mathematical models of acid-base chemistry, a venous blood gas sample and peripheral blood oxygen saturation to calculate arterial acid-base status. It has the potential to replace routine ABG sampling for selected patient cohorts. The aim of this study was to compare v-TAC with ABG, capillary and venous sampling in a patient cohort referred to start non-invasive ventilation (NIV). METHODS: Recruited patients underwent near simultaneous ABG, capillary blood gas (CBG) and venous blood gas (VBG) sampling at day 0, and up to two further occasions (day 1 NIV and discharge). The primary outcome was the reliability of v-TAC sampling compared with ABG, via Bland-Altman analysis, to identify respiratory failure (via PaCO(2)) and to detect changes in PaCO(2) in response to NIV. Secondary outcomes included agreements with pH, sampling success rates and pain. RESULTS: The agreement between ABG and v-TAC/venous PaCO(2) was assessed for 119 matched sampling episodes and 105 between ABG and CBG. Close agreement was shown for v-TAC (mean difference (SD) 0.01 (0.5) kPa), but not for CBG (-0.75 (0.69) kPa) or VBG (+1.00 (0.90) kPa). Longitudinal data for 32 patients started on NIV showed the closest agreement for ABG and v-TAC (R(2)=0.61). v-TAC sampling had the highest first-time success rate (88%) and was less painful than arterial (p<0.0001). CONCLUSION: Mathematical arterialisation of venous samples was easier to obtain and less painful than ABG sampling. Results showed close agreement for PaCO2 and pH and tracked well longitudinally such that the v-TAC method could replace routine ABG testing to recognise and monitor patients with hypercapnic respiratory failure. TRIAL REGISTRATION NUMBER: NCT04072848; www. CLINICALTRIALS: gov.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。