Detailed measurements of oesophageal pressure during mechanical ventilation with an advanced high-resolution manometry catheter

利用先进的高分辨率测压导管对机械通气期间的食管压力进行详细测量。

阅读:1

Abstract

BACKGROUND: Oesophageal pressure (PES) is used for calculation of lung and chest wall mechanics and transpulmonary pressure during mechanical ventilation. Measurements performed with a balloon catheter are suggested as a basis for setting the ventilator; however, measurements are affected by several factors. High-resolution manometry (HRM) simultaneously measures pressures at every centimetre in the whole oesophagus and thereby provides extended information about oesophageal pressure. The aim of the present study was to evaluate the factors affecting oesophageal pressure using HRM. METHODS: Oesophageal pressure was measured using a high-resolution manometry catheter in 20 mechanically ventilated patients (15 in the ICU and 5 in the OR). Different PEEP levels and different sizes of tidal volume were applied while pressures were measured continuously. In 10 patients, oesophageal pressure was also measured using a conventional balloon catheter for comparison. A retrospective analysis of oesophageal pressure measured with HRM in supine and sitting positions in 17 awake spontaneously breathing patients is also included. RESULTS: HRM showed large variations in end-expiratory PES (PESEE) and tidal changes in PES (ΔPES) along the oesophagus. Mean intra-individual difference between the minimum and maximum end-expiratory oesophageal pressure (PESEE at baseline PEEP) and tidal variations in oesophageal pressure (ΔPES at tidal volume 6 ml/kg) recorded by HRM in the different sections of the oesophagus was 23.7 (7.9) cmH(2)O and 7.6 (3.9) cmH(2)O respectively. Oesophageal pressures were affected by tidal volume, level of PEEP, part of the oesophagus included and patient positioning. HRM identified simultaneous increases and decreases in PES within a majority of individual patients. Compared to sitting position, supine position increased PESEE (mean difference 12.3 cmH(2)O), pressure variation within individual patients and cardiac artefacts. The pressure measured with a balloon catheter did not correspond to the average pressure measured with HRM within the same part of the oesophagus. CONCLUSIONS: The intra-individual variability in PESEE and ΔPES is substantial, and as a result, the balloon on the conventional catheter is affected by many different pressures along its length. Oesophageal pressures are not only affected by lung and chest wall mechanics but are a complex product of many factors, which is not obvious during conventional measurements. For correct calculations of transpulmonary pressure, factors influencing oesophageal pressures need to be known. HRM, which is available at many hospitals, can be used to increase the knowledge concerning these factors. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02901158.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。