Diagnostic accuracy of methacholine challenge tests assessing airway hyperreactivity in asthmatic patients - a multifunctional approach

乙酰甲胆碱激发试验评估哮喘患者气道高反应性的诊断准确性——一种多功能方法

阅读:1

Abstract

BACKGROUND: There are few studies comparing diagnostic accuracy of different lung function parameters evaluating dose-response characteristics of methacholine (MCH) challenge tests (MCT) as quantitative outcome of airway hyperreactivity (AHR) in asthmatic patients. The aim of this retrospectively analysis of our database (Clinic Barmelweid, Switzerland) was, to assess diagnostic accuracy of several lung function parameters quantitating AHR by dose-response characteristics. METHODS: Changes in effective specific airway conductance (sG(eff)) as estimate of the degree of bronchial obstruction were compared with concomitantly measured forced expiratory volume in 1 s (FEV(1)) and forced expiratory flows at 50% forced vital capacity (FEF(50)). According to the GINA Guidelines the patients (n = 484) were classified into asthmatic patients (n = 337) and non-asthmatic subjects (n = 147). Whole-body plethysmography (CareFusion, Würzburg, Germany) was performed using ATS-ERS criteria, and for the MCTs a standardised computer controlled protocol with 3 consecutive cumulative provocation doses (PD(1): 0.2 mg; PD(2): 1.0 mg; PD(3): 2.2 mg) was used. Break off criterion for the MCTs were when a decrease in FEV(1) of 20% was reached or respiratory symptoms occurred. RESULTS: In the assessment of AHR, whole-body plethysmography offers in addition to spirometry indices of airways conductance and thoracic lung volumes, which are incorporated in the parameter sG(eff), derived from spontaneous tidal breathing. The cumulative percent dose-responses at each provocation step were at the 1(st) level step (0.2 mg MCH) 3.7 times, at the 2(nd) level step (1 mg MCH) 2.4 times, and at the 3(rd) level step (2.2 mg MCH) 2.0 times more pronounced for sG(eff), compared to FEV(1). A much better diagnostic odds ratio of sG(eff) (7.855) over FEV(1) (6.893) and FEF(50) (4.001) could be found. Moreover, the so-called dysanapsis, and changes of end-expiratory lung volume were found to be important determinants of AHR. CONCLUSIONS: Applying plethysmographic tidal breathing analysis in addition to spirometry in MCTs provides relevant advantages. The absence of deep and maximal inhalations and forced expiratory manoeuvres improve the subject's cooperation and coordination, and provide sensitive and differentiated test results, improving diagnostic accuracy. Moreover, by the combined assessment, pulmonary hyperinflation and dysanapsis can be respected in the differentiation between "asthmatics" and "non-asthmatics".

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。