Biomechanical evaluation of various fixation strategies in oblique lumbar interbody fusion: a finite element analysis

斜位腰椎椎间融合术中不同固定策略的生物力学评价:有限元分析

阅读:1

Abstract

BACKGROUND CONTEXT: Typical oblique lumbar interbody fusion (OLIF) generally employed either the single lateral screw (SLS) or dual pedicle screws (DPS) for instrumentation, each with their own limitations. PURPOSE: The study aimed to investigate the biomechanical properties of two additional fixation strategies including single reverse pedicle screw (SRS) and dual overlapped screws (DOS) compared with SLS and DPS. STUDY DESIGN: A finite element (FE) analysis study. METHODS: A L2-5 finite element model was established and validated with L4/5 as the experimental segment. Four fixations including SLS, SRS, DPS and DOS were established on the segment respectively. The L5's inferior surface was set immobilized. Follower-loaded bending moments were imposed on the superior surface of L2 to record the segment's range of motion (ROM) and maximum stress (MS) on the screws, cage and cortical bone under F-E (flexion and extension), bending (left and right) and rotation (left and right). RESULTS: The model was validated feasible through comparison with previous studies. Regarding the immediate stability: (i) the ROM was significantly lower in DPS and DOS compared to SLS and SRS during F-E and rotations; (ii) compared to DPS, DOS illustrated mildly increased ROM during F-E motions, and left rotation; (iii) compared to SLS, SRS showed an increase of ROM during flexion but a reduction in extension, without obvious distinctions during other motions. Regarding the mechanical response: (i) DPS and DOS illustrated lower MS on the screws, cortical bone and cage than SLS and SRS during most motions; (ii) Compared to DPS, DOS exhibited increased MS during most motions on the screws, cortical bone and cage; (iii) Compared to SLS, SRS demonstrated an increase of MS on the screws during flexion but an reduction during extension, along with decreased MS on cortical bone and cage during most motions. CONCLUSION: Dual-screw systems (DPS and DOS) demonstrated enhanced immediate stability for the segment and mitigated mechanical loading for the instrument compared to single-screw systems (SLS and SRS); For the former, DOS exhibited comparable immediate stability to typical DPS, indicating the potential as a viable alternative; For the later, SRS manifested similar stability to traditional SLS, with less stress loading on the cage and cortical bone, indicating less risk of instrument failure in the long term. CLINICAL SIGNIFICANCE: The study provides biomechanical references to achieve differentiated and individualized instrumentation for patients undergoing OLIF surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。