The effects of Modic-III change on the osseointegration in cervical disc prosthesis: an experimental study in caprine models

Modic-III 改变对颈椎间盘假体骨整合的影响:山羊模型实验研究

阅读:1

Abstract

OBJECTIVE: To quantitatively investigate the effects of Modic-III changes on the porous bone ingrowth at the interface of cervical disc prosthesis using caprine models. METHODS: The Modic-III changes were induced at C3-4 level in eight goats by discectomy, followed by the implantation of cervical disc prostheses, while another eight goats served as a control group. Computed tomography (CT) and X-rays of cervical spine were performed intraoperatively and postoperatively at verify implant placement. The vertebral specimens were examined by micro-CT for histomorphometric quantification, including bone volume fraction (BV/TV), trabecular number (Tb.N), trabecular thickness (Tb.Th). Methylene-blue/acid fuchsin staining, standard hematoxylin and eosin staining, and Masson staining were used for histologic evaluation. Immunohistochemical staining, including osteocalcin (OCN), alkaline phosphate (ALP), and runt-related transcription factor 2 (RUNX2), were also conducted. RESULTS: All goats were followed for a period of 6 months after prosthesis implantation. The rate of prosthesis complications in experimental group was significantly higher than that in control group (37.5% vs. 12.5%, P = 0.046). The histomorphometric parameters of experimental group, including BV/TV, Tb.N, Tb.Th, and bone ingrowth percentage were significantly lower than those of control group. The histologic sections of control group showed the excellent bone ingrowth and close contact between bone and prosthesis interface. By contrast, in experimental group, plenty of interfacial gaps were filled up with abundant fibrous tissue. The immunohistochemical sections of control group demonstrated the bone trabecula was surrounded by numerous osteoblasts, compared with the clear and smooth bone trabecula margin surrounded by few osteoblasts in experimental group. Moreover, the experimental group had significantly lower integrated optical density values of OCN, ALP, and RUNX2 staining. CONCLUSION: The Modic-III changes significantly impaired the osseointegration of artificial cervical disc in caprine models by reducing the number of osteoblasts, BV/TV, Tb.N, Tb.Th, bone ingrowth percentage and down-regulating the expression levels of ALP, Osteocalcin, and Runx-2, possibly leading to more occurrence of prosthesis complications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。